Product Details | ELECTROMAGNETIC RELAY

5945-00-925-8024 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.

Part Alternates: 3S2791G201D11, 95501104211, 5945-00-925-8024, 00-925-8024, 5945009258024, 009258024

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 02 FEB 1966 00-925-8024

Cross Reference | NSN 5945-00-925-8024

Part Number Cage Code Manufacturer
3S2791G201D11 01526 GENICOM CORP
3S2791G201D11 1DUQ5 COMMUNICATIONS INSTRUMENTS INC DIV OF CII TECHNOLOGIES
95501104211 55972 HONEYWELL INTL INC DEFENSE AVIONICS SYSTEMS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-00-925-8024

Technical Data | NSN 5945-00-925-8024

Characteristic Specifications
NONPILE-UP MAIN CONTACT ARRANGEMENT 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 115.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 2.0 AMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD
COIL QUANTITY 1
WINDING QUANTITY 1
WINDING DC RESISTANCE RATING 1.278 KILOHMS NOMINAL SINGLE WINDING
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 38.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
TERMINAL TYPE AND QUANTITY 5 PIN ALL FUNCTIONS
TIME DELAY 0.005 SECONDS NOMINAL FIXED OPERATE TIME 0.003 SECONDS NOMINAL FIXED RELEASE TIME
DUTY TYPE CONTINUOUS
ENVIRONMENTAL PROTECTION HERMETIC
OVERALL LENGTH 0.790 INCHES NOMINAL
OVERALL WIDTH 0.350 INCHES NOMINAL
OVERALL HEIGHT 1.440 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED STUD SINGLE MOUNTING FACILITY
MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 0.412 INCHES NOMINAL SINGLE MOUNTING FACILITY
THREAD SERIES DESIGNATOR UNC SINGLE MOUNTING FACILITY
NOMINAL THREAD SIZE 0.112 INCHES SINGLE MOUNTING FACILITY
THREAD CLASS 2A SINGLE MOUNTING FACILITY

Restrictions/Controls & Freight Information | NSN 5945-00-925-8024

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code SG 403 SCMS/GUED
5215 Thurlow St, Suite 5, Bldg 70C
Wright-Patterson AFB OH 45433
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5945-00-925-8024

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each