5945-01-034-2960 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.

Part Alternates: 46BR0Z1100ACLSIL, 5945-01-034-2960, 01-034-2960, 5945010342960, 010342960

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 22 JAN 1977 01-034-2960

Cross Reference | NSN 5945-01-034-2960

Part Number Cage Code Manufacturer
46BR0Z1100ACLSIL 78277 SIGMA INSTRUMENTS INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-01-034-2960

Technical Data | NSN 5945-01-034-2960

Characteristic Specifications
PILE-UP MAIN CONTACT FORM ARRANGEMENT 2C
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 115.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 5.0 AMPERES AC AND 5.0 AMPERES DC RESISTIVE LOAD
ARC QUENCHING METHOD AIR
COIL QUANTITY 1
WINDING QUANTITY 1
WINDING DC RESISTANCE RATING 1.1 KILOHMS NOMINAL SINGLE WINDING
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 120.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
DUTY TYPE CONTINUOUS
ENVIRONMENTAL PROTECTION DUSTPROOF
OVERALL LENGTH 1.312 INCHES NOMINAL
OVERALL WIDTH 1.312 INCHES NOMINAL
OVERALL HEIGHT 2.650 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 8 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY

Restrictions/Controls & Freight Information | NSN 5945-01-034-2960

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code 86 NASA Kennedy Space Center
Kennedy Space Center, FL 32899
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable