Product Details | REED RELAY

5945-01-042-7384 A relay consisting of an energizing coil and a metallic reed switch mechanism. The reeds serve as both core and contacts, which are not hinged or pivoted and which move by flexure when acted upon by a magnetic field induced by energization of the coil. It may also include a biasing magnet. The biasing magnet, either aids or opposes the movement of the reeds and the opening or closing of the contacts. For items in which actuation is dependent on the resonant frequency of the reeds see RELAY, RESONANT REED. Excludes RELAY, ELECTROMAGNETIC.

Part Alternates: 04900877, 0490-0877, 5945-01-042-7384, 01-042-7384, 5945010427384, 010427384

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 14 JUN 1977 01-042-7384

Demand History | NSN 5945-01-042-7384

Part Number Request Date QTY Origin
5945-01-042-7384 2014-05-128 8 DIBBS
5945-01-042-7384 2014-04-94 1 DIBBS
5945-01-042-7384 2014-03-79 1 DIBBS

Cross Reference | NSN 5945-01-042-7384

Part Number Cage Code Manufacturer
0490-0877 1LQK8 KEYSIGHT TECHNOLOGIES, INC.
0490-0877 28480 HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-01-042-7384

Technical Data | NSN 5945-01-042-7384

Characteristic Specifications
NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 1200.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 15.0 AMPERES DC RESISTIVE LOAD
COIL QUANTITY 1
WINDING QUANTITY 1
WINDING DC RESISTANCE RATING 0.6 OHMS NOMINAL SINGLE WINDING
DUTY TYPE CONTINUOUS
SPECIAL FEATURES ISOTHERMAL

Restrictions/Controls & Freight Information | NSN 5945-01-042-7384

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5945-01-042-7384

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each