Product Details | REED RELAY

5945-01-047-7453 A relay consisting of an energizing coil and a metallic reed switch mechanism. The reeds serve as both core and contacts, which are not hinged or pivoted and which move by flexure when acted upon by a magnetic field induced by energization of the coil. It may also include a biasing magnet. The biasing magnet, either aids or opposes the movement of the reeds and the opening or closing of the contacts. For items in which actuation is dependent on the resonant frequency of the reeds see RELAY, RESONANT REED. Excludes RELAY, ELECTROMAGNETIC.

Part Alternates: 50001455, 5945-01-047-7453, 01-047-7453, 5945010477453, 010477453

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 12 SEP 1977 01-047-7453

Cross Reference | NSN 5945-01-047-7453

Part Number Cage Code Manufacturer
50001455 95036 APPLIED DEVICES CORP
50001455 B1231 BUREAU GESTION HAWK

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-01-047-7453

Technical Data | NSN 5945-01-047-7453

Characteristic Specifications
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 500.0 MILLIAMPERES AC RESISTIVE LOAD
COIL QUANTITY 1
WINDING QUANTITY 1
WINDING DC RESISTANCE RATING 500.0 OHMS NOMINAL SINGLE WINDING
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 5.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
DUTY TYPE CONTINUOUS
ENVIRONMENTAL PROTECTION ANY ACCEPTABLE
OVERALL LENGTH 0.730 INCHES MINIMUM AND 0.790 INCHES MAXIMUM
OVERALL WIDTH 0.220 INCHES MINIMUM AND 0.300 INCHES MAXIMUM
OVERALL HEIGHT 0.275 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 1 TERMINAL SINGLE MOUNTING FACILITY
MANUFACTURERS CODE 95036
DESIGN CONTROL REFERENCE 50001455

Restrictions/Controls & Freight Information | NSN 5945-01-047-7453

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code ZX NAMSA (LI Division)
ZZ
1
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable