Product Details | ELECTROMAGNETIC RELAY

5945-01-267-0815 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.

Part Alternates: M6106/13-009, M610613009, MIL-PRF-6106/13, MILPRF610613, MIL-R-6106/13, MILR610613, 5945-01-267-0815, 01-267-0815, 5945012670815, 012670815

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 04 NOV 1987 01-267-0815

Demand History | NSN 5945-01-267-0815

Part Number Request Date QTY Origin
5945-01-267-0815 2017-03-65 1 DIBBS
5945-01-267-0815 2016-12-364 1 DIBBS
5945-01-267-0815 2016-09-272 1 DIBBS
5945-01-267-0815 2010-07-182 11 DIBBS

Cross Reference | NSN 5945-01-267-0815

Part Number Cage Code Manufacturer
M6106/13-009 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-PRF-6106/13 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-R-6106/13 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-01-267-0815

Technical Data | NSN 5945-01-267-0815

Characteristic Specifications
NONPILE-UP MAIN CONTACT ARRANGEMENT 3 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
NONPILE-UP AUXILIARY CONTACT ARRANGEMENT 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 28.0 DC
AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 28.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 25.0 AMPERES AC AND 25.0 AMPERES DC RESISTIVE LOAD 15.0 AMPERES AC AND 15.0 AMPERES DC INDUCTIVE LOAD 5.0 AMPERES AC AND 5.0 AMPERES DC LAMP LOAD 10.0 AMPERES AC AND 10.0 AMPERES DC MOTOR LOAD
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 2.0 AMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD 500.0 MILLIAMPERES AC AND 500.0 MILLIAMPERES DC LAMP LOAD
ARC QUENCHING METHOD AIR
COIL QUANTITY 1
WINDING QUANTITY 1
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
TERMINAL TYPE AND QUANTITY 11 WIRE HOOK ALL FUNCTIONS
TIME DELAY 0.015 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME
DUTY TYPE CONTINUOUS
ENVIRONMENTAL PROTECTION HERMETIC
OVERALL LENGTH 1.718 INCHES MAXIMUM
OVERALL WIDTH 1.655 INCHES MAXIMUM
OVERALL HEIGHT 1.025 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 4 SLOTTED HOLE SINGLE MOUNTING FACILITY
MOUNTING FACILITY PATTERN RECTANGULAR SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.396 INCHES MINIMUM AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY
MOUNTING SLOT WIDTH 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY
FEATURES PROVIDED POLARIZED
TEST DATA DOCUMENT 81349-MIL-R-6106 SPECIFICATION
SPECIFICATION/STANDARD DATA 81349-MIL-R-6106/13 GOVERNMENT SPECIFICATION
III PURPOSE FOR WHICH DESIGNED GENERAL
III END ITEM IDENTIFICATION MD-1208/G
(NON-CORE DATA) END ITEM SOURCE 04655
III CUBIC MEASURE 2.914 CUBIC INCHES
III UNPACKAGED UNIT WEIGHT 0.180 POUNDS
III FRAGILITY FACTOR MODERATELY RUGGED
III STORAGE TYPE GENERAL PURPOSE WAREHOUSE
III CASE MATERIAL METAL

Restrictions/Controls & Freight Information | NSN 5945-01-267-0815

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TH Defense Supply Center Columbus
Columbus, OH 43215
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5945-01-267-0815

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each