Product Details | ELECTROMAGNETIC RELAY

5945-01-347-0520 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.

Part Alternates: 5945-01-347-0520, 01-347-0520, 5945013470520, 013470520

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 01-347-0520

Cross Reference | NSN 5945-01-347-0520

Part Number Cage Code Manufacturer
1048088-1 3B150 RAYTHEON TECHNICAL SERVICES COMPANY LLC
1048088-1 49956 RAYTHEON COMPANY DBA RAYTHEON
1048088-4 3B150 RAYTHEON TECHNICAL SERVICES COMPANY LLC
1048088-4 49956 RAYTHEON COMPANY DBA RAYTHEON
432-7273 11532 TELEDYNE REYNOLDS, INC. DBA TELEDYNE RELAYS
432-7444 11532 TELEDYNE REYNOLDS, INC. DBA TELEDYNE RELAYS
91652110-97 99699 DRI RELAYS INC. DBA FOREIGN PARENT IS FINANCIERE DE
M39016-11-017M 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39016/11-001M 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39016/11-017L 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39016/11-017P 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39016/11-017P 96906 MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS
MIL-PRF-39016/11 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-R-39016/11 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MILR39016-11 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MSW-179-1 02289 HI-G CO INC SUB OF NYTRONICS INC
MSW-179-1 58614 TYCO ELECTRONICS CORPORATION DBA CII TECHNOLOGIES
MSW-179-4 02289 HI-G CO INC SUB OF NYTRONICS INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-01-347-0520

Technical Data | NSN 5945-01-347-0520

Characteristic Specifications
NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 28.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 500.0 MILLIAMPERES AC AND 1.0 AMPERES DC RESISTIVE LOAD 200.0 MILLIAMPERES DC INDUCTIVE LOAD 100.0 MILLIAMPERES DC LAMP LOAD
ARC QUENCHING METHOD AIR
COIL QUANTITY 1
WINDING QUANTITY 1
WINDING DC RESISTANCE RATING 100.0 OHMS NOMINAL SINGLE WINDING
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 5.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
ENERGIZING ELEMENT POWER RATING 60.0 MILLIWATTS
TERMINAL TYPE AND QUANTITY 8 PIN ALL FUNCTIONS
TIME DELAY 0.004 SECONDS MAXIMUM FIXED OPERATE TIME 0.002 SECONDS MAXIMUM FIXED RELEASE TIME
DUTY TYPE CONTINUOUS
ENVIRONMENTAL PROTECTION HERMETIC AND SALT SPRAY RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT
OVERALL LENGTH 0.375 INCHES MAXIMUM
OVERALL DIAMETER 0.370 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY
SPECIAL FEATURES FAILURE RATE LEVEL OF 1.000 PERCENT PER TEN THOUSAND CYCLES
TEST DATA DOCUMENT 81349-MIL-R-39016 SPECIFICATION
SPECIFICATION/STANDARD DATA 81349-MIL-R-39016/11 GOVERNMENT SPECIFICATION
CRITICALITY CODE JUSTIFICATION FEAT
III PURPOSE FOR WHICH DESIGNED GENERAL
III CUBIC MEASURE 0.040 CUBIC INCHES
III UNPACKAGED UNIT WEIGHT 3.4 GRAMS
III FRAGILITY FACTOR MODERATELY RUGGED
III STORAGE TYPE GENERAL PURPOSE WAREHOUSE
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MIL-PRF-39016/11
MANUFACTURERS CODE 81349
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE M39016/11-017M

Restrictions/Controls & Freight Information | NSN 5945-01-347-0520

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Category Code Description
No Freight Information