Product Details | ELECTROMAGNETIC RELAY

5945-01-347-9874 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.

Part Alternates: M39016/13-095M, M3901613095M, MIL-PRF-39016/13, MILPRF3901613, MIL-R-39016/13, MILR3901613, 5945-01-347-9874, 01-347-9874, 5945013479874, 013479874

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 01-347-9874

Cross Reference | NSN 5945-01-347-9874

Part Number Cage Code Manufacturer
M39016/13-095M 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39016/13-095P 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-PRF-39016/13 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-R-39016/13 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-01-347-9874

Technical Data | NSN 5945-01-347-9874

Characteristic Specifications
NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 28.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 2.0 AMPERES DC RESISTIVE LOAD 300.0 MILLIAMPERES DC INDUCTIVE LOAD 100.0 MILLIAMPERES DC LAMP LOAD
COIL QUANTITY 1
WINDING QUANTITY 1
WINDING DC RESISTANCE RATING 39.6 OHMS MINIMUM AND 48.4 OHMS MAXIMUM SINGLE WINDING
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 5.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
TERMINAL TYPE AND QUANTITY 8 PIN ALL FUNCTIONS
TIME DELAY 0.004 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME
DUTY TYPE CONTINUOUS
ENVIRONMENTAL PROTECTION DUSTPROOF
OVERALL LENGTH 1.062 INCHES MAXIMUM
OVERALL WIDTH 0.310 INCHES MAXIMUM
OVERALL HEIGHT 0.320 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 0.850 INCHES NOMINAL SINGLE MOUNTING FACILITY
UNTHREADED MOUNTING HOLE DIAMETER 0.091 INCHES MINIMUM AND 0.101 INCHES MAXIMUM SINGLE MOUNTING FACILITY
SPECIAL FEATURES FAILURE RATE 1.0 PERCENT
TEST DATA DOCUMENT 81349-MIL-R-39016 SPECIFICATION
SPECIFICATION/STANDARD DATA 81349-MIL-R-39016/13 GOVERNMENT SPECIFICATION
CRITICALITY CODE JUSTIFICATION FEAT
III PURPOSE FOR WHICH DESIGNED GENERAL
III CUBIC MEASURE 0.104 CUBIC INCHES
III UNPACKAGED UNIT WEIGHT 4.82 GRAMS
III FRAGILITY FACTOR MODERATELY RUGGED
III STORAGE TYPE GENERAL PURPOSE WAREHOUSE
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MIL-PRF-39016/13
MANUFACTURERS CODE 81349
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE M39016/13-095M

Restrictions/Controls & Freight Information | NSN 5945-01-347-9874

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Category Code Description
No Freight Information