NSN 5945-01-562-4241 CM1AR24V, CM1A-R-24V , V23074A1002A402
Product Details | ELECTROMAGNETIC RELAY
5945-01-562-4241 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.
Part Alternates: CM1AR24V, CM1A-R-24V , V23074A1002A402, V23074-A1002-A402, 0042358, 8-1393292-9, 5945-01-562-4241, 01-562-4241, 5945015624241, 015624241, 813932929
Electrical and Electronic Equipment Components | Relays and Solenoids
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 08 APR 2008 | 01-562-4241 | 32512 ( RELAY, ELECTROMAGNETIC ) |
Cross Reference | NSN 5945-01-562-4241
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 0042358 | F0016 | PANHARD GENERAL DEFENSE |
| 0042358 | F9059 | PANHARD GENERAL DEFENSE - ACTIVITEAUVERLAND |
| 8-1393292-9 | 77342 | TYCO ELECTRONICS CORPORATION |
| 8-1393292-9 | F0286 | TYCO ELECTRONICS FRANCE SAS |
| CM1A-R-24V | S7781 | PANASONIC ELECTRIC WORKS CO LTD |
| V23074-A1002-A402 | 77342 | TYCO ELECTRONICS CORPORATION |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5945-01-562-4241
Related Products | NSN 5945-01-562-4241
Technical Data | NSN 5945-01-562-4241
| Characteristic | Specifications |
|---|---|
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 24.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.0 AMPERES DC RESISTIVE LOAD |
| COIL QUANTITY | 1 |
| WINDING DC RESISTANCE RATING | 354.0 OHMS NOMINAL SINGLE WINDING |
| ENERGIZING ELEMENT POWER RATING | 1.6 WATTS |
| DUTY TYPE | CONTINUOUS |
| OVERALL LENGTH | 0.906 INCHES NOMINAL |
| OVERALL WIDTH | 0.610 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
Restrictions/Controls & Freight Information | NSN 5945-01-562-4241
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||