NSN 5945-01-613-9463 05005A3008 , 90010502, 9001-05-02
Product Details | REED RELAY
5945-01-613-9463 A relay consisting of an energizing coil and a metallic reed switch mechanism. The reeds serve as both core and contacts, which are not hinged or pivoted and which move by flexure when acted upon by a magnetic field induced by energization of the coil. It may also include a biasing magnet. The biasing magnet, either aids or opposes the movement of the reeds and the opening or closing of the contacts. For items in which actuation is dependent on the resonant frequency of the reeds see RELAY, RESONANT REED. Excludes RELAY, ELECTROMAGNETIC.
Part Alternates: 05005A3008 , 90010502, 9001-05-02 , 5945-01-613-9463, 01-613-9463, 5945016139463, 016139463
Electrical and Electronic Equipment Components | Relays and Solenoids
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 2012325 | 01-613-9463 | 30544 ( RELAY, REED ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5945-01-613-9463
Technical Data | NSN 5945-01-613-9463
| Characteristic | Specifications |
|---|---|
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| TERMINAL TYPE AND QUANTITY | 4 PIN ALL FUNCTIONS |
| DUTY TYPE | CONTINUOUS |
| OVERALL LENGTH | 0.750 INCHES MAXIMUM |
| OVERALL WIDTH | 0.200 INCHES MAXIMUM |
| OVERALL HEIGHT | 0.300 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 PRINTED CIRCUIT TERMINAL SINGLE MOUNTING FACILITY |
| SPECIAL FEATURES | DESCRIPTION: SWITCHING VOLTAGE: 200V, SWITCHING CURRENT: 0.5A, 2A CARRY CURRENT, 10W CONTACT RATING, 150 MOHM MAX STATIC CONTACT RESISTANCE; COIL: 5V TYP, 10V MAX, RESISTANCE: 450 OHMS MIN. 550 OHMS MAX, 3.75V MAX OPERATING VOLTAGE, 0.8 MIN. RELEASE VOLTAGE, 50MW NOMINAL INPUT POWER; OPERATING TEMP RANGE: -40 TO +85 DEG C. |
| III END ITEM IDENTIFICATION | NSN: 6625-01-565-9819, PROGRAM SET, APPLICATION; NEXT ASSEMBLY 05005A1030 USED ON 05005A0000 |
| III PART NAME ASSIGNED BY CONTROLLING AGENCY | RELAY, REED |
| III PRECIOUS MATERIAL | RUTHENIUM |
| III PRECIOUS MATERIAL AND LOCATION | CONTACTS RUTHENIUM |
Restrictions/Controls & Freight Information | NSN 5945-01-613-9463
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
| Precious Metals Indicator Code: | P | Item contains platinum family metals |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061300 | CIRCUIT BREAKER/SWITCH NOI |
| Less than car load rating | P | 77.5 |
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 72D | unknown |
| Originating Activity Code | PA | Marine Corps Logistics Base Albany, GA 31704-1128 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5945-01-613-9463
| Category | Code | Description |
|---|---|---|
| Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
| Combat Essentiality Code | 5 | Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency. |
| Materiel Management Code | B | All CommoditiesDefense Logistics Agency, (DLA,) |
| Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DM | U.S. Marine Corps |
| Service Organization | M | U.S. Marine Corps |
| Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
| Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |