Product Details | REACTOR

5950-00-027-1661 A coil or coils usually constructed with cores having low magnetic reluctance, whose primary purpose is to furnish an inductive impedance in power or audio frequency circuit ranging from zero to 20 kilohertz (kilocycles). Includes audio frequency and power filter chokes, audio reactors and swinging chokes. Does not include transformers or coils used above audio frequency range. Excludes SATURABLE REACTOR. For reactors with air cores, see COIL (as modified).

Part Alternates: 5950-00-027-1661, 00-027-1661, 5950000271661, 000271661

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 00-027-1661

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-027-1661

Technical Data | NSN 5950-00-027-1661

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 2 STANDOFF, SOLDER LUG
RATING METHOD ELECTRICAL SINGLE COMPONENT SINGLE WINDING
WINDING OPERATING CURRENT 280.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
DC RESISTANCE RATING IN OHMS 102.000 SINGLE COMPONENT SINGLE WINDING
INDUCTANCE RATING 12.40 HENRY NOMINAL SINGLE COMPONENT SINGLE WINDING
WINDING QUANTITY 1 SINGLE COMPONENT
INDUCTANCE TYPE FIXED
MOUNTING METHOD FLANGE AND UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
MOUNTING HOLE DIAMETER 0.312 INCHES NOMINAL SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 8.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 4.187 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE HERMETICALLY SEALED
BODY LENGTH 9.687 INCHES NOMINAL
BODY HEIGHT 7.344 INCHES NOMINAL
BODY WIDTH 5.406 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
SPECIAL FEATURES TERMINAL HEIGHT 0.781 IN.
III END ITEM IDENTIFICATION ARSR1

Restrictions/Controls & Freight Information | NSN 5950-00-027-1661

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Category Code Description
No Freight Information