Product Details | REACTOR-TRANSFORMER

5950-00-062-1499 A component consisting of two or more electrically distinct items. One or more items are made of one or more coils which function as a reactor; at least one other item is made of a tapped coil or two or more coils which function as a transformer. The items may have a common core, but are not magnetically coupled.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: A17232, S5163, S-5163, 7901833-00, 5950-00-062-1499, 00-062-1499, 5950000621499, 790183300, 000621499

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 20 JUN 1967 00-062-1499

Cross Reference | NSN 5950-00-062-1499

Part Number Cage Code Manufacturer
7901833-00 90536 LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN
A17232 00144 TE CONNECTIVITY NETWORKS, INC. DIV ADC TELECOMMUNICATIONS SALES,
S-5163 80023 VISHAY HIREL SYSTEMS LLC DIV MARSHALL

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-062-1499

Technical Data | NSN 5950-00-062-1499

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 11 STANDOFF, THREADED STUD
(NON-CORE DATA) COMPONENT NAME AND QUANTITY 1 COIL AND 1 TRANSFORMER
RATING METHOD ELECTRICAL 1ST COMPONENT SINGLE PRIMARY ELECTRICAL 1ST COMPONENT SINGLE SECONDARY ELECTRICAL 2ND COMPONENT SINGLE WINDING
WINDING OPERATING VOLTAGE 120.00 AC VOLTS NOMINAL OR 208.00 AC VOLTS NOMINAL 1ST COMPONENT SINGLE PRIMARY 10.00 AC VOLTS NOMINAL 1ST COMPONENT SINGLE SECONDARY 0.70 AC VOLTS NOMINAL 2ND COMPONENT SINGLE WINDING
WINDING OPERATING CURRENT 60.5 AMPERES AC MAXIMUM 1ST COMPONENT SINGLE SECONDARY 80.0 AMPERES DC MAXIMUM 2ND COMPONENT SINGLE WINDING
DC RESISTANCE RATING IN OHMS 0.006 2ND COMPONENT SINGLE WINDING
INDUCTANCE RATING 0.80 MILLIHENRIES MINIMUM 2ND COMPONENT SINGLE WINDING
FREQUENCY RATING 360.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM 1ST COMPONENT 2.4 KILOHERTZ NOMINAL 2ND COMPONENT
WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY 1ST COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO THREE PHASE 1ST COMPONENT SINGLE PHASE TO SINGLE PHASE 2ND COMPONENT
MOUNTING METHOD THREADED HOLE ALL GROUPINGS
MOUNTING FACILITY QUANTITY 8 ALL GROUPINGS
THREAD SERIES DESIGNATOR UNC ALL GROUPINGS
NOMINAL THREAD SIZE 0.250 INCHES ALL GROUPINGS
THREAD QUANTITY PER INCH 20 ALL GROUPINGS
(NON-CORE DATA) THREAD CLASS 2B ALL GROUPINGS
(NON-CORE DATA) THREAD DIRECTION RIGHT-HAND ALL GROUPINGS
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 6.690 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 5.420 INCHES MINIMUM AND 5.460 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP
INCLOSURE TYPE HERMETICALLY SEALED WITH OIL
BODY LENGTH 7.920 INCHES MAXIMUM
BODY WIDTH 6.650 INCHES MAXIMUM
OVERALL HEIGHT 7.310 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
III MAXIMUM OPERATING TEMP 105.0 DEG CELSIUS

Restrictions/Controls & Freight Information | NSN 5950-00-062-1499

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-00-062-1499

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each