Product Details | POWER TRANSFORMER

5950-00-069-0314 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 6720136000, 672-0136-000, 9501219400, 950-1219-400, 5950-00-069-0314, 00-069-0314, 5950000690314, 000690314

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-069-0314

Cross Reference | NSN 5950-00-069-0314

Part Number Cage Code Manufacturer
672-0136-000 13499 ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS
672-0136-000 95105 ROCKWELL COLLINS, INC. DIV GOVERNMENT SYSTEMS - DALLAS
950-1219-400 27777 L-3 COMMUNICATIONS CORPORATION DBA WARRIOR SYSTEMS DIVISION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-069-0314

Technical Data | NSN 5950-00-069-0314

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 29 SOLDER STUD
(NON-CORE DATA) WINDING TAP LOCATION CENTER TAP SINGLE COMPONENT ALL SECONDARY
WINDING OPERATING VOLTAGE 76.80 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 46.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 28.20 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY 19.80 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT 1.2 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 1.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY 0.3 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY 1.4 AMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
FREQUENCY RATING 45.0 HERTZ MINIMUM AND 430.0 HERTZ MAXIMUM SINGLE COMPONENT
WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 9 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD FLANGE AND UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 10 SINGLE GROUP
MOUNTING HOLE DIAMETER 0.203 INCHES NOMINAL SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 5.047 INCHES MINIMUM AND 5.078 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 3.995 INCHES MINIMUM AND 4.005 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE HERMETICALLY SEALED
BODY LENGTH 5.406 INCHES MINIMUM AND 5.468 INCHES MAXIMUM
BODY WIDTH 5.031 INCHES MINIMUM AND 5.093 INCHES MAXIMUM
OVERALL HEIGHT 5.531 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
SPECIAL FEATURES 1 PRIMARY WINDING; 9 SECONDARY WINDINGS
TEST DATA DOCUMENT 13499-672-0135-000 DRAWING
III MAXIMUM OPERATING TEMP 105.0 DEG CELSIUS
(NON-CORE DATA) UNPACKAGED UNIT WEIGHT 18.000 POUNDS
(NON-CORE DATA) CUBIC MEASURE 12.8 CUBIC FEET

Restrictions/Controls & Freight Information | NSN 5950-00-069-0314

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-00-069-0314

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each