Product Details | AUDIO FREQUENCY TRANSFORMER

5950-00-079-1714 A transformer which is designed so that part or all of its range of operating frequencies is 20 kilohertz (kilocycles) and below. The maximum value may extend into the radio frequency range. It is generally used in the input, output, amplifier, or oscillator stages of audio and sonar devices.

Part Alternates: P5220706, 130649, 130-649, 3320257, 3320-257, 5950-00-079-1714, 00-079-1714, 5950000791714, 000791714

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1961 00-079-1714

Cross Reference | NSN 5950-00-079-1714

Part Number Cage Code Manufacturer
130-649 90073 CMC ELECTRONICS INC
3320-257 90073 CMC ELECTRONICS INC
P5220706 B0556 COBELDA SA

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-079-1714

Technical Data | NSN 5950-00-079-1714

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 4 SOLDER STUD
IMPEDANCE RATING IN OHMS 1200.0 NOMINAL SINGLE COMPONENT SINGLE PRIMARY 100000.0 MINIMUM SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING 1.0 KILOHERTZ MAXIMUM SINGLE COMPONENT
(NON-CORE DATA) FREQUENCY RESPONSE TOLERANCE IN DECIBELS -4.0 TO 40.0 SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
MOUNTING METHOD THREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
THREAD SERIES DESIGNATOR UNC SINGLE GROUP
NOMINAL THREAD SIZE 0.112 INCHES SINGLE GROUP
THREAD QUANTITY PER INCH 40 SINGLE GROUP
(NON-CORE DATA) THREAD CLASS 2B SINGLE GROUP
(NON-CORE DATA) THREAD DIRECTION RIGHT-HAND SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 0.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 0.953 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE OPEN
BODY LENGTH 1.250 INCHES MAXIMUM
BODY HEIGHT 1.812 INCHES MAXIMUM
BODY WIDTH 1.188 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
III TRANSFORMER FUNCTION INPUT
MANUFACTURERS CODE 90073
DESIGN CONTROL REFERENCE 3320-257

Restrictions/Controls & Freight Information | NSN 5950-00-079-1714

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-00-079-1714

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityPStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each