Product Details | POWER TRANSFORMER

5950-00-080-5655 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: GA51689, 9986620, 5950-00-080-5655, 00-080-5655, 5950000805655, 000805655

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-080-5655

Cross Reference | NSN 5950-00-080-5655

Part Number Cage Code Manufacturer
9986620 18876 U S ARMY AVIATION AND MISSILE COMMAND
GA51689 06KW9 LUCENT TECHNOLOGIES INC DBA FEDERAL MARKETING GROUP
GA51689 3B4M0 LUCENT TECHNOLOGIES INC CORPORATE HEADQUARTERS
GA51689 64959 AMERICAN TELEPHONE AND TELEGRAPH CO

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-080-5655

Technical Data | NSN 5950-00-080-5655

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 6 WIRE HOOK
WINDING OPERATING VOLTAGE 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY 6.40 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY
WINDING OPERATING CURRENT 2.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD THREADED STUD SINGLE GROUP
MOUNTING FACILITY QUANTITY 2 SINGLE GROUP
THREAD SERIES DESIGNATOR UNC SINGLE GROUP
NOMINAL THREAD SIZE 0.164 INCHES SINGLE GROUP
THREAD QUANTITY PER INCH 32 SINGLE GROUP
(NON-CORE DATA) THREAD CLASS 2A SINGLE GROUP
(NON-CORE DATA) THREAD TOLERANCE CLASS 2A EXTERNAL SINGLE GROUP
(NON-CORE DATA) THREAD LENGTH 0.656 INCHES NOMINAL SINGLE GROUP
(NON-CORE DATA) THREAD DIRECTION RIGHT-HAND SINGLE GROUP
DISTANCE BETWEEN MOUNTING FACILITY CENTERS 1.376 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE HERMETICALLY SEALED
BODY LENGTH 2.250 INCHES NOMINAL
BODY HEIGHT 1.969 INCHES NOMINAL
BODY WIDTH 2.219 INCHES NOMINAL
OVERALL LENGTH 2.906 INCHES NOMINAL
OVERALL HEIGHT 1.969 INCHES NOMINAL
OVERALL WIDTH 2.219 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
MANUFACTURERS CODE 64959
DESIGN CONTROL REFERENCE GA51689

Restrictions/Controls & Freight Information | NSN 5950-00-080-5655

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating P 77.5
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable