NSN 5950-00-094-5526 V3800, V7400, 664034761500
Product Details | ELECTROMAGNET
5950-00-094-5526 A winding with a soft, laminated, or pressed powdered iron core, which generates an extremely strong field of magnetic force when current is passed through the winding. The field dissipates almost completely when the current is interrupted. For electric magnets used for lifting, see MAGNET, LIFTING, ELECTRIC.
Part Alternates: V3800, V7400, 664034761500, 6640-3476-1500, 5950-00-094-5526, 00-094-5526, 5950000945526, 000945526
Electrical and Electronic Equipment Components | Coils and Transformers
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 06 DEC 1972 | 00-094-5526 | 02813 ( ELECTROMAGNET ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5950-00-094-5526
Related Products | NSN 5950-00-094-5526
Technical Data | NSN 5950-00-094-5526
| Characteristic | Specifications |
|---|---|
| SPECIAL FEATURES | 2 COILS 0.500 OHMS AND 141 AMPS MAX CURRENT EACH; COILS WATER COOLED; 20KW AND 10KW MAX POWER CONSUMPTION PER COIL AT MAX OPERATING TEMP; 71V WORKIG WITH TRUNNION SUPPORTED YOKE; 1 THERMAL SWITCH EACH COIL; MOUNTED ON ROTATING BASE; 56.250 INCHES HIGH BY 42.750 INCHES WIDE BY 48 INCHES DEEP; FURNISHED WITH 2 POLE CAPS, 2 MATING BARS, 4 EYEBOLT HOLE COVERS |
Restrictions/Controls & Freight Information | NSN 5950-00-094-5526
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||
Management | NSN 5950-00-094-5526
| Category | Code | Description |
|---|---|---|
| Materiel Category and Inventory Manager | B | Ground Forces Support Materiel (Other Support Materiel) |
| Appropriation and Budget Activity | Q | Other Support Equipment |
| Management Inventory Segment | 1 | REPARABLE ITEMS (Exclusive of Insurance and Provisioning Items.) This code will be used to identify serviceable or unserviceable items of a durable nature which when unserviceable normally can be repaired economically by depots or lower echelons of maintenance. |
| Specific Group/Generic Code | U | POL, Soldier and Combat Support Systems |
| Weapons Systems/End Item or Homogeneous Group | UD | POL Test Equipment |
| Accounting Requirements Code | N | Nonexpendable item. An item of Army property coded with an ARC of?N?in the AMDF. Nonexpendable items require property book accountability after issue from the stock record account. Commercial and fabricated items similar to items coded ?N? in the AMDF are considered nonexpendable items. |
| Source of Supply | FPZ | San Antonio Air Logistics Center Kelly AFB, TX 78241-5000 |
| Agency | DA | Department of the Army |
| Service Organization | A | U.S. Army |
| Acquisition Advice Codes | N | RESTRICTED REQUISITIONING-DISPOSAL (Service/Agency use only.) # Discontinued items no longer authorized for issue except on the specific approval of the Service inventory manager. Requisitions may be submitted in accordance with Service requisitioning procedures in instances where valid requirements exist and replacing item data has not been furnished. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |