Product Details | SATURABLE REACTOR

5950-00-133-8908 An item whose inductance value is controlled by electrical means. It depends on the action of the electromagnet flux produced by the control winding upon the effective permeability of the core. It contains two or more windings, at least one of which must be a control winding. For items designed to be used in conjunction with a rectifier(s) for amplification purposes, see AMPLIFIER, MAGNETIC.

Part Alternates: 50003012501, 50003-0125-01, 5950-00-133-8908, 00-133-8908, 5950001338908, 001338908

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 26 FEB 1969 00-133-8908

Cross Reference | NSN 5950-00-133-8908

Part Number Cage Code Manufacturer
50003-0125-01 79343 SCIENCE APPLICATIONS INTERNATIONAL CORPORATION
50003-0125-01 93568 HARSCO CORP BMY-COMBAT SYSTEMS DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-133-8908

Technical Data | NSN 5950-00-133-8908

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 4 TAB, SOLDER LUG
WINDING OPERATING VOLTAGE 110.00 AC VOLTS MINIMUM AND 400.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
FREQUENCY RATING 60.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING SHIELDING METHOD INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 CONTROL SINGLE COMPONENT
MOUNTING METHOD UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 2 SINGLE GROUP
MOUNTING HOLE DIAMETER 0.120 INCHES NOMINAL SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 2.375 INCHES NOMINAL
OVERALL LENGTH 2.875 INCHES NOMINAL
OVERALL HEIGHT 1.937 INCHES NOMINAL
OVERALL WIDTH 1.500 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
(NON-CORE DATA) INCLOSURE MATERIAL PLASTIC

Restrictions/Controls & Freight Information | NSN 5950-00-133-8908

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code PA Marine Corps Logistics Base
Albany, GA 31704-1128
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-00-133-8908

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each