Product Details | POWER TRANSFORMER

5950-00-134-5776 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: S509159, S-509159, SMB6622061, SM-B-662206-1, 5950-00-134-5776, 00-134-5776, 5950001345776, 001345776

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 00-134-5776

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-134-5776

Technical Data | NSN 5950-00-134-5776

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 12 WIRE LEAD
WINDING OPERATING VOLTAGE 12.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY 10.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 8.20 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY
WINDING OPERATING CURRENT 1.0 AMPERES AC NOMINAL SINGLE COMPONENT 1ST PRIMARY
FREQUENCY RATING 20.0 KILOHERTZ NOMINAL SINGLE COMPONENT
MAXIMUM TRANSFORMER POWER RATING 10.0 VOLT-AMPERE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 2 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD THREADED HOLE ALL GROUPINGS
MOUNTING FACILITY QUANTITY 4 ALL GROUPINGS
THREAD SERIES DESIGNATOR UNC ALL GROUPINGS
NOMINAL THREAD SIZE 0.112 INCHES ALL GROUPINGS
(NON-CORE DATA) THREAD CLASS 2B ALL GROUPINGS
(NON-CORE DATA) THREAD DIRECTION RIGHT-HAND ALL GROUPINGS
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.090 INCHES MINIMUM AND 1.110 INCHES MAXIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.090 INCHES MINIMUM AND 1.110 INCHES MAXIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 1.400 INCHES MAXIMUM
BODY HEIGHT 0.950 INCHES MINIMUM AND 0.970 INCHES MAXIMUM
BODY WIDTH 1.400 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
TEST DATA DOCUMENT 80063-SM-B-662206 DRAWING
III MAXIMUM OPERATING TEMP 125.0 DEG CELSIUS
(NON-CORE DATA) UNPACKAGED UNIT WEIGHT 116.0 GRAMS
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION MOISTURE RESISTANT

Restrictions/Controls & Freight Information | NSN 5950-00-134-5776

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Category Code Description
No Freight Information