Product Details | POWER TRANSFORMER

5950-00-137-0814 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: PAK220, 2652666, 561749, 5641, 8451981, 845198-1, 5950-00-137-0814, 00-137-0814, 5950001370814, 001370814

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 19 JUL 1971 00-137-0814

Cross Reference | NSN 5950-00-137-0814

Part Number Cage Code Manufacturer
2652666 10001 NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT
561749 56232 LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN
5641 13483 PRECISION ELECTRONICS, INC.
5641 53711 NAVAL SEA SYSTEMS COMMAND
845198-1 00779 TYCO ELECTRONICS CORPORATION
845198-1 0LSP2 SPECTRUM CONTROL, INC. DBA ELECTROMAGNETIC DIVISION
PAK220 15634 MAGNETIKA, INC
PAK220 80223 UNITED TRANSFORMER CORP SUB OF OPT INDUSTRIES INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-137-0814

Technical Data | NSN 5950-00-137-0814

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 6 THREADED STUD
WINDING OPERATING VOLTAGE 1.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 9.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 440.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT 11.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD FLANGE AND SLOT SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
MOUNTING SLOT WIDTH 0.218 INCHES NOMINAL SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 5.700 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE HERMETICALLY SEALED
BODY LENGTH 6.250 INCHES NOMINAL
BODY HEIGHT 3.750 INCHES NOMINAL
BODY WIDTH 4.750 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
MANUFACTURERS CODE 10001
DESIGN CONTROL REFERENCE 2652666

Restrictions/Controls & Freight Information | NSN 5950-00-137-0814

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeYInformation is in the Hazardous Materials Information System (HMIS)
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-00-137-0814

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each