Product Details | POWER TRANSFORMER

5950-00-137-8095 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: TW63192, TW-63192, 1503, 1512400001, 151-240-0001, 6501153, 650-1153, 5950-00-137-8095, 00-137-8095, 5950001378095, 001378095

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 21 JUL 1971 00-137-8095

Demand History | NSN 5950-00-137-8095

Part Number Request Date QTY Origin
5950-00-137-8095 2010-01-19 6 DIBBS
TW63192 2009-07-188 6 US
5950-00-137-8095 2009-03-75 2 DIBBS
5950-00-137-8095 2009-02-36 4 DIBBS
5950-00-137-8095 2007-12-338 2 DIBBS
5950-00-137-8095 2007-09-264 2 DIBBS
5950-00-137-8095 2007-03-75 4 DIBBS

Cross Reference | NSN 5950-00-137-8095

Part Number Cage Code Manufacturer
1503 95266 OECO, LLC DBA PACIFIC SCIENTIFIC OECO
151-240-0001 95542 NORTHROP GRUMMAN SYSTEMS CORPORATION
650-1153 10581 STANDEX ELECTRONICS INC.
650-1153 21908 NCR CORP POWER SYSTEMS DIV
TW-63192 1L8V1 MAGNETIKA, INC DBA MANUFACTURING BRANCH
TW63192 02640 MAGNETIKA

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-137-8095

Technical Data | NSN 5950-00-137-8095

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 6 TURRET
WINDING OPERATING VOLTAGE 78.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 10.20 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT 100.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 200.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD THREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 2 SINGLE GROUP
THREAD SERIES DESIGNATOR UNC SINGLE GROUP
NOMINAL THREAD SIZE 0.112 INCHES SINGLE GROUP
THREAD QUANTITY PER INCH 40 SINGLE GROUP
(NON-CORE DATA) THREAD CLASS 3A SINGLE GROUP
DISTANCE BETWEEN MOUNTING FACILITY CENTERS 0.531 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 1.000 INCHES MAXIMUM
BODY HEIGHT 1.375 INCHES MAXIMUM
BODY WIDTH 1.000 INCHES MAXIMUM
OVERALL LENGTH 1.000 INCHES MAXIMUM
OVERALL HEIGHT 1.625 INCHES MAXIMUM
OVERALL WIDTH 1.000 INCHES MAXIMUM
MANUFACTURERS CODE 95542
MFR SOURCE CONTROLLING REFERENCE 151-240-0001

Restrictions/Controls & Freight Information | NSN 5950-00-137-8095

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code KE Naval ICP
Philadelphia, PA 19111
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-00-137-8095

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each