NSN 5950-00-223-1826 A19713F, 00-223-1826, 002231826
Product Details | REACTOR-TRANSFORMER
5950-00-223-1826 A component consisting of two or more electrically distinct items. One or more items are made of one or more coils which function as a reactor; at least one other item is made of a tapped coil or two or more coils which function as a transformer. The items may have a common core, but are not magnetically coupled.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station
Part Alternates: A19713F, 5950-00-223-1826, 00-223-1826, 5950002231826, 002231826
Electrical and Electronic Equipment Components | Coils and Transformers
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 01 JAN 1961 | 00-223-1826 | 02918 ( REACTOR-TRANSFORMER ) |
Cross Reference | NSN 5950-00-223-1826
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| A19713F | 06845 | RAYTHEON COMPANY DBA RAYTHEON |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5950-00-223-1826
Related Products | NSN 5950-00-223-1826
Technical Data | NSN 5950-00-223-1826
| Characteristic | Specifications |
|---|---|
| TERMINAL TYPE AND QUANTITY | 6 TAB, SOLDER LUG |
| WINDING OPERATING CURRENT | 0.1 AMPERES DC NOMINAL SINGLE COMPONENT SINGLE WINDING |
| DC RESISTANCE RATING IN OHMS | 145.000 SINGLE COMPONENT SINGLE WINDING |
| INDUCTANCE RATING | 5.00 HENRY NOMINAL SINGLE COMPONENT 1ST WINDING 0.35 HENRY NOMINAL SINGLE COMPONENT 2ND WINDING |
| FREQUENCY RATING | 300.0 HERTZ MINIMUM AND 4000.0 HERTZ MAXIMUM SINGLE COMPONENT |
| PRIMARY TO SECONDARY TURN RATIO | 1.445 TO 1 SINGLE COMPONENT |
| MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
| OVERALL LENGTH | 3.906 INCHES NOMINAL |
| OVERALL HEIGHT | 2.000 INCHES NOMINAL |
| OVERALL WIDTH | 2.000 INCHES NOMINAL |
| (NON-CORE DATA) INCLOSURE MATERIAL | ALUMINUM |
| MANUFACTURERS CODE | 06845 |
| DESIGN CONTROL REFERENCE | A19713F |
Restrictions/Controls & Freight Information | NSN 5950-00-223-1826
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
| Less than car load rating | P | 77.5 |
| Less than truck load rating | W | Rating Variable |
| Water commodity Code | 595 | unknown |
| Originating Activity Code | XX | |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |