NSN 5950-00-236-7129 B843510002, B843510-002, 860078
Product Details | REACTOR
5950-00-236-7129 A coil or coils usually constructed with cores having low magnetic reluctance, whose primary purpose is to furnish an inductive impedance in power or audio frequency circuit ranging from zero to 20 kilohertz (kilocycles). Includes audio frequency and power filter chokes, audio reactors and swinging chokes. Does not include transformers or coils used above audio frequency range. Excludes SATURABLE REACTOR. For reactors with air cores, see COIL (as modified).
Part Alternates: B843510002, B843510-002, 860078, 3T449, 5950-00-236-7129, 00-236-7129, 5950002367129, 002367129
Electrical and Electronic Equipment Components | Coils and Transformers
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 28 MAY 1973 | 00-236-7129 | 00724 ( REACTOR ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5950-00-236-7129
Related Products | NSN 5950-00-236-7129
Technical Data | NSN 5950-00-236-7129
| Characteristic | Specifications |
|---|---|
| INDUCTANCE RATING | 30.00 MILLIHENRIES NOMINAL SINGLE COMPONENT 1ST WINDING |
| OVERALL LENGTH | 1.820 INCHES MAXIMUM |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.180 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| INDUCTANCE TYPE | FIXED |
| TERMINAL TYPE AND QUANTITY | 4 WIRE LEAD |
| THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| FREQUENCY RATING | 1.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
| OVERALL HEIGHT | 1.180 INCHES MAXIMUM |
| MOUNTING METHOD | BRACKET SINGLE GROUP AND THREADED HOLE SINGLE GROUP |
| OVERALL WIDTH | 0.920 INCHES MAXIMUM |
| NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
| RATING METHOD | ELECTRICAL SINGLE COMPONENT 1ST WINDING |
| WINDING QUANTITY | 2 SINGLE COMPONENT |
| MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
| INCLOSURE TYPE | FULLY INCLOSED |
Restrictions/Controls & Freight Information | NSN 5950-00-236-7129
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
| Less than car load rating | ||
| Less than truck load rating | W | Rating Variable |
| Water commodity Code | 595 | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |