Product Details | REACTOR-TRANSFORMER

5950-00-239-7535 A component consisting of two or more electrically distinct items. One or more items are made of one or more coils which function as a reactor; at least one other item is made of a tapped coil or two or more coils which function as a transformer. The items may have a common core, but are not magnetically coupled.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 73C812001, 73C812-001, 5950-00-239-7535, 00-239-7535, 5950002397535, 002397535

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 05 NOV 1969 00-239-7535

Cross Reference | NSN 5950-00-239-7535

Part Number Cage Code Manufacturer
73C812-001 04660 AIL SYSTEMS INC SUB OF EATON CORP
73C812-001 72964 ROBERT M HADLEY COMPANY INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-239-7535

Technical Data | NSN 5950-00-239-7535

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 9 TURRET
(NON-CORE DATA) COMPONENT NAME AND QUANTITY 1 COIL AND 1 TRANSFORMER
(NON-CORE DATA) WINDING TAP LOCATION MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
RATING METHOD ELECTRICAL SINGLE COMPONENT SINGLE WINDING
WINDING OPERATING VOLTAGE 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY 26.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING CURRENT 940.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY 17.0 AMPERES DC NOMINAL SINGLE COMPONENT SINGLE WINDING
DC RESISTANCE RATING IN OHMS 0.025 SINGLE COMPONENT SINGLE WINDING
INDUCTANCE RATING 0.20 MILLIHENRIES MINIMUM SINGLE COMPONENT SINGLE WINDING
FREQUENCY RATING 2.4 KILOHERTZ NOMINAL 1ST COMPONENT 380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM 2ND COMPONENT
WINDING SHIELDING METHOD PRIMARY AND SECONDARY SHIELDED AND BROUGHT OUT TO TERMINAL ALL COMPONENTS
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD THREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 6 SINGLE GROUP
THREAD SERIES DESIGNATOR UNC SINGLE GROUP
NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP
(NON-CORE DATA) THREAD CLASS 2B SINGLE GROUP
(NON-CORE DATA) THREAD DIRECTION RIGHT-HAND SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE FULLY INCLOSED
OVERALL LENGTH 3.990 INCHES MINIMUM AND 4.010 INCHES MAXIMUM
OVERALL HEIGHT 2.469 INCHES MAXIMUM
OVERALL WIDTH 1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
III MAXIMUM OPERATING TEMP 95.0 DEG CELSIUS
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION SALT SPRAY RESISTANT
MANUFACTURERS CODE 04660
DESIGN CONTROL REFERENCE 73C812-001

Restrictions/Controls & Freight Information | NSN 5950-00-239-7535

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code KE Naval ICP
Philadelphia, PA 19111
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-00-239-7535

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each