NSN 5950-00-239-7535 73C812001, 73C812-001, 00-239-7535
Product Details | REACTOR-TRANSFORMER
5950-00-239-7535 A component consisting of two or more electrically distinct items. One or more items are made of one or more coils which function as a reactor; at least one other item is made of a tapped coil or two or more coils which function as a transformer. The items may have a common core, but are not magnetically coupled.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station
Part Alternates: 73C812001, 73C812-001, 5950-00-239-7535, 00-239-7535, 5950002397535, 002397535
Electrical and Electronic Equipment Components | Coils and Transformers
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 05 NOV 1969 | 00-239-7535 | 02918 ( REACTOR-TRANSFORMER ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5950-00-239-7535
Related Products | NSN 5950-00-239-7535
Technical Data | NSN 5950-00-239-7535
| Characteristic | Specifications |
|---|---|
| TERMINAL TYPE AND QUANTITY | 9 TURRET |
| (NON-CORE DATA) COMPONENT NAME AND QUANTITY | 1 COIL AND 1 TRANSFORMER |
| (NON-CORE DATA) WINDING TAP LOCATION | MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
| RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
| WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY 26.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| WINDING OPERATING CURRENT | 940.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY 17.0 AMPERES DC NOMINAL SINGLE COMPONENT SINGLE WINDING |
| DC RESISTANCE RATING IN OHMS | 0.025 SINGLE COMPONENT SINGLE WINDING |
| INDUCTANCE RATING | 0.20 MILLIHENRIES MINIMUM SINGLE COMPONENT SINGLE WINDING |
| FREQUENCY RATING | 2.4 KILOHERTZ NOMINAL 1ST COMPONENT 380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM 2ND COMPONENT |
| WINDING SHIELDING METHOD | PRIMARY AND SECONDARY SHIELDED AND BROUGHT OUT TO TERMINAL ALL COMPONENTS |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
| MOUNTING FACILITY QUANTITY | 6 SINGLE GROUP |
| THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
| NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
| (NON-CORE DATA) THREAD CLASS | 2B SINGLE GROUP |
| (NON-CORE DATA) THREAD DIRECTION | RIGHT-HAND SINGLE GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| INCLOSURE TYPE | FULLY INCLOSED |
| OVERALL LENGTH | 3.990 INCHES MINIMUM AND 4.010 INCHES MAXIMUM |
| OVERALL HEIGHT | 2.469 INCHES MAXIMUM |
| OVERALL WIDTH | 1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| III MAXIMUM OPERATING TEMP | 95.0 DEG CELSIUS |
| III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | SALT SPRAY RESISTANT |
| MANUFACTURERS CODE | 04660 |
| DESIGN CONTROL REFERENCE | 73C812-001 |
Restrictions/Controls & Freight Information | NSN 5950-00-239-7535
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
| Less than car load rating | ||
| Less than truck load rating | W | Rating Variable |
| Water commodity Code | 595 | unknown |
| Originating Activity Code | KE | Naval ICP Philadelphia, PA 19111 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5950-00-239-7535
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |



