NSN 5950-00-256-0553 GT14R1593, 00-256-0553, 002560553
Product Details | POWER AUTOTRANSFORMER TRANSFORMER
5950-00-256-0553 A transformer which incorporates the primary and secondary functions into a single winding, which is common to both input and output circuits, and is designed to change the relationship of volts and amperes between the entire winding and its taps. Includes multiple winding transformers of like design and items in which a variation of the turns ratio or inductive ratio of inductive coupling is accomplished by connection to fixed terminals. Also, includes items having a provision for mechanically changing the turns ratio in progressive increments, by means of a shaft, voltage taps, ratio adjuster, or devices of similar design. Excludes TRANSFORMER (1), POWER; TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station
Part Alternates: GT14R1593, 5950-00-256-0553, 00-256-0553, 5950002560553, 002560553
Electrical and Electronic Equipment Components | Coils and Transformers
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 27 JUN 1973 | 00-256-0553 | 36166 ( TRANSFORMER, POWER AUTOTRANSFORMER ) |
Cross Reference | NSN 5950-00-256-0553
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| GT14R1593 | 26512 | NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN AEROSPACE |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5950-00-256-0553
Technical Data | NSN 5950-00-256-0553
| Characteristic | Specifications |
|---|---|
| TERMINAL TYPE AND QUANTITY | 7 THREADED STUD |
| (NON-CORE DATA) WINDING TAP LOCATION | TAP W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY OUTPUT CENTER TAP SINGLE COMPONENT SINGLE SECONDARY |
| WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT 4.00 AC VOLTS NOMINAL AND 26.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT 20.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| WINDING OPERATING CURRENT | 100.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY, FIXED AUTOTRANSFORMER TYPE AND 1 SECONDARY SINGLE COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| MOUNTING METHOD | FLANGE AND SLOT SINGLE GROUP |
| MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
| MOUNTING SLOT WIDTH | 0.183 INCHES NOMINAL SINGLE GROUP |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| INCLOSURE TYPE | OPEN |
| BODY LENGTH | 2.250 INCHES NOMINAL |
| BODY HEIGHT | 2.120 INCHES NOMINAL |
| BODY WIDTH | 2.250 INCHES NOMINAL |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| (NON-CORE DATA) CUBIC MEASURE | 11.2 CUBIC INCHES |
Restrictions/Controls & Freight Information | NSN 5950-00-256-0553
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
| Less than car load rating | ||
| Less than truck load rating | W | Rating Variable |
| Water commodity Code | 595 | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5950-00-256-0553
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | X | SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |