Product Details | POTENTIAL TRANSFORMER

5950-00-273-9425 A transformer designed to connect an electrical instrument to a power line or other high potential alternating current source for the purpose of voltage measurement or control.

Part Alternates: 118338, 1183-38, 5950-00-273-9425, 00-273-9425, 5950002739425, 002739425

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 04 AUG 1973 00-273-9425

Cross Reference | NSN 5950-00-273-9425

Part Number Cage Code Manufacturer
1183-38 30242 AVTECH TYEE, INC. DBA A DIVISION OF TRANSDIGM GROUP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-273-9425

Technical Data | NSN 5950-00-273-9425

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 5 PIN
(NON-CORE DATA) WINDING TAP LOCATION MULTIPLE TAPS W/CENTER TAP SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
PRIMARY TO SECONDARY TURN RATIO 3.4 TO 1 SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
MOUNTING METHOD TERMINAL SINGLE GROUP
INCLOSURE TYPE OPEN
RELIABILITY INDICATOR NOT ESTABLISHED
(NON-CORE DATA) DUMMY TERMINAL QUANTITY 2
MANUFACTURERS CODE 30242
DESIGN CONTROL REFERENCE 1183-38

Restrictions/Controls & Freight Information | NSN 5950-00-273-9425

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating P 77.5
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code TA Sacramento Air Logistics Center
McClellan AFB, CA 95652-5609
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code Z unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable