Product Details | POWER TRANSFORMER

5950-00-410-7799 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: SMD2015896, SM-D-2015896, T5709, 42934, 5950-00-410-7799, 00-410-7799, 5950004107799, 004107799

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 22 JUL 1970 00-410-7799

Cross Reference | NSN 5950-00-410-7799

Part Number Cage Code Manufacturer
42934 73386 FREED TRANSFORMER COMPANY
SM-D-2015896 80063 US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS
T5709 07119 KAPITAL MAGNETIC CORP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-410-7799

Technical Data | NSN 5950-00-410-7799

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 5 TAB, SOLDER LUG
(NON-CORE DATA) WINDING TAP LOCATION CENTER TAP SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY 28.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING CURRENT 1.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING 47.5 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT
WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO SECONDARY CENTER TAP SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD THREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
THREAD SERIES DESIGNATOR UNC SINGLE GROUP
NOMINAL THREAD SIZE 0.164 INCHES SINGLE GROUP
(NON-CORE DATA) THREAD CLASS 2B SINGLE GROUP
(NON-CORE DATA) THREAD DIRECTION RIGHT-HAND SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.182 INCHES MINIMUM AND 2.192 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.995 INCHES MINIMUM AND 2.005 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 2.672 INCHES MINIMUM AND 2.704 INCHES MAXIMUM
BODY HEIGHT 2.250 INCHES MAXIMUM
BODY WIDTH 2.484 INCHES MINIMUM AND 2.516 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
III MAXIMUM OPERATING TEMP 130.0 DEG CELSIUS

Restrictions/Controls & Freight Information | NSN 5950-00-410-7799

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable