NSN 5950-00-495-4663 APS064, APS-064, 890827
Product Details | POWER TRANSFORMER
5950-00-495-4663 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station
Part Alternates: APS064, APS-064, 890827, 5950-00-495-4663, 00-495-4663, 5950004954663, 004954663
Electrical and Electronic Equipment Components | Coils and Transformers
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 18 JUN 1971 | 00-495-4663 | 32496 ( TRANSFORMER, POWER ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5950-00-495-4663
Technical Data | NSN 5950-00-495-4663
| Characteristic | Specifications |
|---|---|
| TERMINAL TYPE AND QUANTITY | 27 PIN |
| (NON-CORE DATA) WINDING TAP LOCATION | TAP W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY TAP W/O CENTER TAP SINGLE COMPONENT ALL SECONDARY |
| WINDING OPERATING VOLTAGE | 31.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 46.90 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 17.90 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY 17.90 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY 188.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| WINDING OPERATING CURRENT | 310.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 1.1 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY 178.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY 189.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
| WINDING POWER RATING | 22.0 WATTS SINGLE COMPONENT SINGLE PRIMARY |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 8 SECONDARY SINGLE COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
| NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
| THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
| (NON-CORE DATA) THREAD CLASS | 2B SINGLE GROUP |
| (NON-CORE DATA) THREAD DIRECTION | RIGHT-HAND SINGLE GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.060 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| INCLOSURE TYPE | FULLY INCLOSED |
| BODY LENGTH | 4.250 INCHES NOMINAL |
| BODY HEIGHT | 2.370 INCHES NOMINAL |
| BODY WIDTH | 2.950 INCHES NOMINAL |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| SPECIAL FEATURES | 5TH SECONDARY 10.5V 118 MA,6TH SEC 10.5V 275 MA,7TH SEC 71.0V 1.5A,8TH SEC 77.5V 1.68A; WEAPON SYSTEM ESSENTIAL |
| CRITICALITY CODE JUSTIFICATION | FEAT |
| III MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
| (NON-CORE DATA) UNPACKAGED UNIT WEIGHT | 3.000 POUNDS |
| III END ITEM IDENTIFICATION | WSD: AIRCRAFT, PHANTOM F-4 |
Restrictions/Controls & Freight Information | NSN 5950-00-495-4663
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | Y | The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
| Less than car load rating | ||
| Less than truck load rating | W | Rating Variable |
| Water commodity Code | 595 | unknown |
| Originating Activity Code | TA | Sacramento Air Logistics Center McClellan AFB, CA 95652-5609 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |