Product Details | POWER TRANSFORMER

5950-00-504-9048 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 225C1831, 225C183-1, 6413, 5950-00-504-9048, 00-504-9048, 5950005049048, 005049048

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 00-504-9048

Demand History | NSN 5950-00-504-9048

Part Number Request Date QTY Origin
6413 2018-02-52 10 United States
6413 2018-02-52 10 United States

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-504-9048

Technical Data | NSN 5950-00-504-9048

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 5 SOLDER STUD AND 4 TAB, SOLDER LUG
(NON-CORE DATA) WINDING TAP LOCATION CENTER TAP SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE 135.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT 60.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 200.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY 2.25 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
FREQUENCY RATING 200.0 HERTZ MINIMUM AND 1.0 KILOHERTZ MAXIMUM SINGLE COMPONENT
WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD FLANGE AND UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
MOUNTING HOLE DIAMETER 0.188 INCHES NOMINAL SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.812 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.188 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE HERMETICALLY SEALED WITH OIL
BODY LENGTH 3.062 INCHES NOMINAL
BODY HEIGHT 3.188 INCHES NOMINAL
BODY WIDTH 2.562 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED

Restrictions/Controls & Freight Information | NSN 5950-00-504-9048

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Category Code Description
No Freight Information