Product Details | POWER TRANSFORMER

5950-00-655-2737 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 5950-00-655-2737, 00-655-2737, 5950006552737, 006552737

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 00-655-2737

Cross Reference | NSN 5950-00-655-2737

Part Number Cage Code Manufacturer
0062408 89926 NEW HOLLAND CONSTRUCTION
062408 89926 NEW HOLLAND CONSTRUCTION
221-001-260 75138 SHERJOR INC
230A614G01 79500 WESTINGHOUSE ELECTRIC CORP
3300539 80064 NAVAL SHIP SYSTEMS COMMAND
5516 75138 SHERJOR INC
5516GRP1 75138 SHERJOR INC
62408 89926 NEW HOLLAND CONSTRUCTION
78J478GP1 11660 WESTINGHOUSE ELECTRIC CORP CONTROL BUSINESS UNIT
CD19R3889 11660 WESTINGHOUSE ELECTRIC CORP CONTROL BUSINESS UNIT
MIL-T-17221 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
NBA61-512-214 01406 ALLIS CHALMERS CORP
NBA61-512-214GRP4 92392 ALLIS-CHALMERS CORP
S230A614G01 11660 WESTINGHOUSE ELECTRIC CORP CONTROL BUSINESS UNIT

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-655-2737

Technical Data | NSN 5950-00-655-2737

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 5 WIRE LEAD
(NON-CORE DATA) WINDING TAP LOCATION CENTER TAP SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE 450.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
MAXIMUM TRANSFORMER POWER RATING 10.0 KILOVOLT-AMPERE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 5 SINGLE GROUP
MOUNTING HOLE DIAMETER 0.438 INCHES NOMINAL SINGLE GROUP
DISTANCE BETWEEN MOUNTING FACILITY CENTERS 7.250 INCHES NOMINAL AND 4.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 16.000 INCHES NOMINAL
BODY HEIGHT 6.250 INCHES NOMINAL
BODY WIDTH 8.625 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
III COOLING METHOD SELF-COOLED

Restrictions/Controls & Freight Information | NSN 5950-00-655-2737

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Category Code Description
No Freight Information