NSN 5950-00-702-9264 16530631, 1653063-1, 00-702-9264
Product Details | POWER TRANSFORMER
5950-00-702-9264 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station
Part Alternates: 16530631, 1653063-1, 5950-00-702-9264, 00-702-9264, 5950007029264, 007029264
Electrical and Electronic Equipment Components | Coils and Transformers
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 00-702-9264 | 32496 ( TRANSFORMER, POWER ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5950-00-702-9264
Technical Data | NSN 5950-00-702-9264
| Characteristic | Specifications |
|---|---|
| TERMINAL TYPE AND QUANTITY | 13 SOLDER STUD |
| (NON-CORE DATA) WINDING TAP LOCATION | CENTER TAP SINGLE COMPONENT 3RD SECONDARY TAP W/O CENTER TAP SINGLE COMPONENT ALL PRIMARY |
| WINDING OPERATING VOLTAGE | 3.50 AC VOLTS NOMINAL AND 22.50 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST PRIMARY 18.50 AC VOLTS NOMINAL AND 22.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| WINDING FUNCTION AND QUANTITY | 2 PRIMARY AND 3 SECONDARY SINGLE COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| MOUNTING METHOD | THREADED STUD SINGLE GROUP |
| MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
| THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
| NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
| THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
| (NON-CORE DATA) THREAD CLASS | 2A SINGLE GROUP |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.812 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| BODY LENGTH | 1.438 INCHES MAXIMUM |
| BODY OUTSIDE DIAMETER | 2.250 INCHES MAXIMUM |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| SPECIAL TEST FEATURES | NAVORD OD41152 |
| REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY SPECIAL TEST FEATURES |
| MANUFACTURERS CODE | 56232 |
| DESIGN CONTROL REFERENCE | 1653063-1 |
Restrictions/Controls & Freight Information | NSN 5950-00-702-9264
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||