Product Details | AUDIO FREQUENCY TRANSFORMER

5950-00-761-6365 A transformer which is designed so that part or all of its range of operating frequencies is 20 kilohertz (kilocycles) and below. The maximum value may extend into the radio frequency range. It is generally used in the input, output, amplifier, or oscillator stages of audio and sonar devices.

Part Alternates: T10400, 5950-00-761-6365, 00-761-6365, 5950007616365, 007616365

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 15 OCT 1972 00-761-6365

Cross Reference | NSN 5950-00-761-6365

Part Number Cage Code Manufacturer
T10400 34764 SCIENTIFIC RADIO SYSTEMS INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-761-6365

Technical Data | NSN 5950-00-761-6365

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 5 WIRE LEAD
WINDING OPERATING CURRENT 20.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
IMPEDANCE RATING IN OHMS 20.0 NOMINAL SINGLE COMPONENT SINGLE PRIMARY 8.0 NOMINAL SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING 300.0 HERTZ MINIMUM AND 3.0 KILOHERTZ MAXIMUM SINGLE COMPONENT
(NON-CORE DATA) FREQUENCY RESPONSE TOLERANCE IN DECIBELS -3.0 TO 3.0 SINGLE COMPONENT
MAXIMUM TRANSFORMER POWER RATING 4.0 WATTS SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
MOUNTING METHOD FLANGE AND UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 2 SINGLE GROUP
MOUNTING HOLE DIAMETER 0.188 INCHES NOMINAL SINGLE GROUP
DISTANCE BETWEEN MOUNTING FACILITY CENTERS 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE OPEN
OVERALL LENGTH 2.060 INCHES NOMINAL
OVERALL HEIGHT 1.200 INCHES NOMINAL
OVERALL WIDTH 1.250 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
MANUFACTURERS CODE 34764
DESIGN CONTROL REFERENCE T10400

Restrictions/Controls & Freight Information | NSN 5950-00-761-6365

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating P 77.5
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code XG USCG Engineering Logistics Center
Baltimore, MD 21226-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable