NSN 5950-00-937-9531 C8233, CT101875, CT101875A
Product Details | POWER TRANSFORMER
5950-00-937-9531 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station
Part Alternates: C8233, CT101875, CT101875A, SMC540721, SM-C-540721, SMD686837, SM-D-686837, 5950-00-937-9531, 00-937-9531, 5950009379531, 009379531
Electrical and Electronic Equipment Components | Coils and Transformers
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 15 FEB 1967 | 00-937-9531 | 32496 ( TRANSFORMER, POWER ) |
Cross Reference | NSN 5950-00-937-9531
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5950-00-937-9531
Technical Data | NSN 5950-00-937-9531
| Characteristic | Specifications |
|---|---|
| TERMINAL TYPE AND QUANTITY | 19 PIN |
| (NON-CORE DATA) WINDING TAP LOCATION | TAP W/O CENTER TAP SINGLE COMPONENT 4TH SECONDARY CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
| WINDING OPERATING VOLTAGE | 5.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 9.19 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 79.18 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY 212.10 AC VOLTS MINIMUM AND 619.17 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY 4.80 DC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
| WINDING OPERATING CURRENT | 150.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 150.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY 50.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY 40.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
| FREQUENCY RATING | 3.8 KILOHERTZ MINIMUM AND 4.2 KILOHERTZ MAXIMUM SINGLE COMPONENT |
| WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 1 CONTROL AND 6 SECONDARY SINGLE COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
| MOUNTING FACILITY QUANTITY | 3 SINGLE GROUP |
| THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
| NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
| (NON-CORE DATA) THREAD CLASS | 2B SINGLE GROUP |
| (NON-CORE DATA) THREAD DIRECTION | RIGHT-HAND SINGLE GROUP |
| MOUNTING BOLT CIRCLE DIAMETER | 1.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| INCLOSURE TYPE | FULLY INCLOSED |
| BODY OUTSIDE DIAMETER | 1.969 INCHES MINIMUM AND 2.031 INCHES MAXIMUM |
| OVERALL LENGTH | 1.094 INCHES MINIMUM AND 1.156 INCHES MAXIMUM |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| SPECIAL FEATURES | 1 PRIMARY; 1 BIAS; & 6 SECONDARY WINDINGS |
| III MAXIMUM OPERATING TEMP | 85.0 DEG CELSIUS |
| (NON-CORE DATA) UNPACKAGED UNIT WEIGHT | 5.000 OUNCES |
Restrictions/Controls & Freight Information | NSN 5950-00-937-9531
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
| Less than car load rating | ||
| Less than truck load rating | W | Rating Variable |
| Water commodity Code | 595 | unknown |
| Originating Activity Code | CL | U.S. Army Communications-Electronics Fort Monmouth, NJ 07703-5006 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |