5950-00-947-2356 An item whose inductance value is controlled by electrical means. It depends on the action of the electromagnet flux produced by the control winding upon the effective permeability of the core. It contains two or more windings, at least one of which must be a control winding. For items designed to be used in conjunction with a rectifier(s) for amplification purposes, see AMPLIFIER, MAGNETIC.

Part Alternates: GE05SR, GE-05-SR , 77364921, 7736492-1, 7736492P0001, 7736492P1, 5950-00-947-2356, 00-947-2356, 5950009472356, 009472356

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 25 MAR 1966 00-947-2356

Cross Reference | NSN 5950-00-947-2356

Part Number Cage Code Manufacturer
7736492-1 99971 LOCKHEED MARTIN CORP NAVAL ELECTRONICS & SURVEILLANCE
7736492P0001 99971 LOCKHEED MARTIN CORP NAVAL ELECTRONICS & SURVEILLANCE
7736492P1 99971 LOCKHEED MARTIN CORP NAVAL ELECTRONICS & SURVEILLANCE
GE-05-SR 98675 ESPEY MFG. & ELECTRONICS CORP.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-947-2356

Technical Data | NSN 5950-00-947-2356

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 8 TAB, SOLDER LUG
FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 2 PRIMARY AND 2 CONTROL SINGLE COMPONENT
MOUNTING METHOD UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
MOUNTING HOLE DIAMETER 0.187 INCHES NOMINAL SINGLE GROUP
INCLOSURE TYPE FULLY INCLOSED
RELIABILITY INDICATOR NOT ESTABLISHED

Restrictions/Controls & Freight Information | NSN 5950-00-947-2356

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating P 77.5
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code SG 403 SCMS/GUED
5215 Thurlow St, Suite 5, Bldg 70C
Wright-Patterson AFB OH 45433
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code Z unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable