Product Details | POWER TRANSFORMER

5950-00-964-6744 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: K210T303A, 2325215, 23-25-215, 24491, 24-491, 5950-00-964-6744, 00-964-6744, 5950009646744, 009646744

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 27 MAY 1966 00-964-6744

Cross Reference | NSN 5950-00-964-6744

Part Number Cage Code Manufacturer
23-25-215 08125 U S DEPT OF TRANSPORTATION FEDERAL AVIATION ADMINISTRATION
23-25-215 55814 SOLA BASIC INDUSTRIES INC SOLA ELECTRIC DIV
24-491 55814 SOLA BASIC INDUSTRIES INC SOLA ELECTRIC DIV
K210T303A 82187 NATIONAL WEATHER SERVICE DBA NATIONAL WEATHER SERVICE OHD1

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-964-6744

Technical Data | NSN 5950-00-964-6744

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 8 TERMINAL BLOCK W/SCREWS
WINDING OPERATING VOLTAGE 95.00 AC VOLTS MINIMUM AND 130.00 AC VOLTS MAXIMUM SINGLE COMPONENT ALL PRIMARY 118.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY
FREQUENCY RATING 60.0 HERTZ NOMINAL SINGLE COMPONENT
MAXIMUM TRANSFORMER POWER RATING 1.5 KILOVOLT-AMPERE SINGLE COMPONENT
WINDING SHIELDING METHOD EXTERNAL INCLOSURE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 2 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD FLANGE AND SLOT SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
MOUNTING SLOT WIDTH 0.438 INCHES NOMINAL SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.938 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 11.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE PARTIALLY INCLOSED, DOUBLE SHELL
BODY LENGTH 19.313 INCHES NOMINAL
BODY HEIGHT 9.031 INCHES NOMINAL
BODY WIDTH 10.562 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED

Restrictions/Controls & Freight Information | NSN 5950-00-964-6744

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:NThe item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).
Category Code Description
No Freight Information