Product Details | REACTOR

5950-01-006-9519 A coil or coils usually constructed with cores having low magnetic reluctance, whose primary purpose is to furnish an inductive impedance in power or audio frequency circuit ranging from zero to 20 kilohertz (kilocycles). Includes audio frequency and power filter chokes, audio reactors and swinging chokes. Does not include transformers or coils used above audio frequency range. Excludes SATURABLE REACTOR. For reactors with air cores, see COIL (as modified).

Part Alternates: 5950-01-006-9519, 01-006-9519, 5950010069519, 010069519

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 01-006-9519

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-006-9519

Technical Data | NSN 5950-01-006-9519

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 2 TAB, SOLDER LUG
WINDING OPERATING CURRENT 7.5 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
DC RESISTANCE RATING IN OHMS 0.065 SINGLE COMPONENT SINGLE WINDING
INDUCTANCE RATING 4.50 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
WINDING QUANTITY 1 SINGLE COMPONENT
INDUCTANCE TYPE FIXED
MOUNTING METHOD THREADED STUD SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
THREAD SERIES DESIGNATOR UNC SINGLE GROUP
NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP
THREAD QUANTITY PER INCH 32 SINGLE GROUP
(NON-CORE DATA) THREAD CLASS 3A SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 2.313 INCHES NOMINAL
BODY HEIGHT 3.125 INCHES NOMINAL
BODY WIDTH 2.062 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
MANUFACTURERS CODE 09017
DESIGN CONTROL REFERENCE 600627-01

Restrictions/Controls & Freight Information | NSN 5950-01-006-9519

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Category Code Description
No Freight Information