Product Details | POWER TRANSFORMER

5950-01-012-6860 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: BX10010, BX-10010, SA0126860, SA0126-860, 172250, 403678, 5950-01-012-6860, 01-012-6860, 5950010126860, 010126860

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 16 NOV 1975 01-012-6860

Cross Reference | NSN 5950-01-012-6860

Part Number Cage Code Manufacturer
172250 64196 VOLTAMPERE CORP
403678 12909 CARDION INC
403678 20284 TARGET CORPORATION DBA TARGET
BX-10010 85323 BALTIMORE TRANSFORMER COMPANY
SA0126-860 54991 ASCHBACHER AND ASSOCIATES INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-012-6860

Technical Data | NSN 5950-01-012-6860

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 20 WIRE LEAD
(NON-CORE DATA) WINDING TAP LOCATION MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT ALL PRIMARY CENTER TAP SINGLE COMPONENT ALL SECONDARY
WINDING OPERATING VOLTAGE 32.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 32.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 25.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY 68.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY 110.00 AC VOLTS NOMINAL AND 125.00 AC VOLTS NOMINAL AND 130.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY
WINDING OPERATING CURRENT 850.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY 450.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY 1.75 AMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY 300.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING POWER RATING 27.2 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY 14.4 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY 43.8 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY 20.4 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY
FREQUENCY RATING 50.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM SINGLE COMPONENT
MAXIMUM TRANSFORMER POWER RATING 111.7 VOLT-AMPERE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 2 PRIMARY AND 5 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD THREADED STUD SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
THREAD SERIES DESIGNATOR UNF SINGLE GROUP
NOMINAL THREAD SIZE 0.190 INCHES SINGLE GROUP
(NON-CORE DATA) THREAD CLASS 2A SINGLE GROUP
(NON-CORE DATA) THREAD DIRECTION RIGHT-HAND SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE HERMETICALLY SEALED
BODY LENGTH 3.940 INCHES NOMINAL
BODY HEIGHT 5.250 INCHES NOMINAL
BODY WIDTH 3.380 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
SPECIAL FEATURES TWO PRIMARY WINDINGS; FIVE SECONDARY WINDINGS AND FIRST,THIRD,FOURTH AND FIFTH SECONDARIES HAVE CENTER TAP CONNECTED TO TERMINAL NUMBER 10

Restrictions/Controls & Freight Information | NSN 5950-01-012-6860

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code 48 Federal Aviation Administration
Oklahoma City, OK 73125
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-01-012-6860

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each