Product Details | POWER TRANSFORMER

5950-01-055-3984 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: C15899, PEI 8157, PEI8157, TTI11563, TTI-11563, 10132732 , 25P22318801, 25P223188-01, 5950-01-055-3984, 01-055-3984, 5950010553984, 010553984

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 04 FEB 1978 01-055-3984

Cross Reference | NSN 5950-01-055-3984

Part Number Cage Code Manufacturer
25P223188-01 98738 HERLEY CHICAGO DBA STEWART WARNER ELECTRONICS
C15899 72149 ELECTRONIC TRANSFORMER CORP.
PEI 8157 13483 PRECISION ELECTRONICS, INC.
TTI-11563 96253 TRANSFORMER TECHNICIANS INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-055-3984

Technical Data | NSN 5950-01-055-3984

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 13 EYELET
(NON-CORE DATA) WINDING TAP LOCATION NEUTRAL TAP SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE 20.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 20.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 6.20 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT 689.6 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY 541.9 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY 4.03 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING POWER RATING 14.0 WATTS SINGLE COMPONENT 1ST SECONDARY 11.0 WATTS SINGLE COMPONENT 2ND SECONDARY 25.0 WATTS SINGLE COMPONENT 3RD SECONDARY
FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO THREE PHASE SINGLE COMPONENT
MOUNTING METHOD BRACKET AND UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 2 SINGLE GROUP
MOUNTING HOLE DIAMETER 0.177 INCHES MINIMUM AND 0.197 INCHES MAXIMUM SINGLE GROUP
DISTANCE BETWEEN MOUNTING FACILITY CENTERS 1.215 INCHES MINIMUM AND 1.235 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE HERMETICALLY SEALED
BODY HEIGHT 1.365 INCHES MINIMUM AND 1.385 INCHES MAXIMUM
BODY WIDTH 1.615 INCHES MINIMUM AND 1.635 INCHES MAXIMUM
OVERALL LENGTH 1.234 INCHES MINIMUM AND 1.266 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
III TRANSFORMER WINDING CONNECTION TYPE WYE-WYE
III MAXIMUM OPERATING TEMP 170.0 DEG CELSIUS
(NON-CORE DATA) CUBIC MEASURE 5.0 CUBIC INCHES
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION VIBRATION RESISTANT

Restrictions/Controls & Freight Information | NSN 5950-01-055-3984

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-01-055-3984

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each