Product Details | POWER TRANSFORMER

5950-01-098-9288 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 21907, 21907A, 5950-01-098-9288, 01-098-9288, 5950010989288, 010989288

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 09 AUG 1980 01-098-9288

Cross Reference | NSN 5950-01-098-9288

Part Number Cage Code Manufacturer
21907 30377 SMITHS AEROSPACE INC. ELECTRONIC SYSTEMS-GRAND RAPIDS
21907A 30377 SMITHS AEROSPACE INC. ELECTRONIC SYSTEMS-GRAND RAPIDS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-098-9288

Technical Data | NSN 5950-01-098-9288

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 12 WIRE LEAD
(NON-CORE DATA) WINDING TAP LOCATION CENTER TAP SINGLE COMPONENT 1ST SECONDARY CENTER TAP SINGLE COMPONENT 2ND SECONDARY CENTER TAP SINGLE COMPONENT SINGLE PRIMARY CENTER TAP SINGLE COMPONENT ALL TERTIARY
WINDING OPERATING VOLTAGE 23.00 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT 3.4 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 200.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
FREQUENCY RATING 20.0 KILOHERTZ NOMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 2 SECONDARY AND 1 TERTIARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 1 SINGLE GROUP
MOUNTING HOLE DIAMETER 0.130 INCHES MINIMUM SINGLE GROUP
INCLOSURE TYPE OPEN
OVERALL LENGTH 0.690 INCHES MAXIMUM
OVERALL DIAMETER 1.310 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED

Restrictions/Controls & Freight Information | NSN 5950-01-098-9288

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description