Product Details | POWER TRANSFORMER

5950-01-107-6087 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: PEI6658, 240863, 24086-3, 2993921, 3155974, 0029LLHDET748, 0029-LL-HDE-T748, 5950-01-107-6087, 01-107-6087, 5950011076087, 011076087

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 10 FEB 1981 01-107-6087

Demand History | NSN 5950-01-107-6087

Part Number Request Date QTY Origin
24086-3 2019-06-164 1 DIBBS
PEI6658 2019-06-164 1 DIBBS
24086-3 2019-06-153 1 DIBBS
PEI6658 2019-06-153 1 DIBBS

Cross Reference | NSN 5950-01-107-6087

Part Number Cage Code Manufacturer
0029-LL-HDE-T748 81994 PHILADELPHIA NAVAL SHIPYARD
24086-3 030B1 JET ENGINEERING INC. DBA
24086-3 12745 WESTAMP INC
2993921 53711 NAVAL SEA SYSTEMS COMMAND
3155974 10001 NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT
PEI6658 13483 PRECISION ELECTRONICS, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-107-6087

Technical Data | NSN 5950-01-107-6087

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 3 BUS (BAR) CONDUCTOR
(NON-CORE DATA) WINDING TAP LOCATION NEUTRAL TAP SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE 300.00 AC VOLTS NOMINAL AND 330.00 AC VOLTS NOMINAL AND 360.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING CURRENT 12.0 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO THREE PHASE SINGLE COMPONENT
MOUNTING METHOD UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 6 SINGLE GROUP
MOUNTING HOLE DIAMETER 0.312 INCHES NOMINAL SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 8.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 3.844 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE FULLY INCLOSED
OVERALL LENGTH 13.000 INCHES MAXIMUM
OVERALL HEIGHT 9.250 INCHES MAXIMUM
OVERALL WIDTH 8.680 INCHES MAXIMUM
FEATURES PROVIDED W/OVERLOAD PROTECTION
RELIABILITY INDICATOR NOT ESTABLISHED
III MAXIMUM OPERATING TEMP 60.0 DEG CELSIUS
(NON-CORE DATA) UNPACKAGED UNIT WEIGHT 45.000 POUNDS
(NON-CORE DATA) CUBIC MEASURE 385.9 CUBIC INCHES
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION HUMIDITY RESISTANT AND VIBRATION RESISTANT AND CORROSION RESISTANT

Restrictions/Controls & Freight Information | NSN 5950-01-107-6087

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code ZA Australia
ZB
ZC
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-01-107-6087

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each