NSN 5950-01-123-0660 ST30852, 11364, 3211805001
Product Details | TRANSFORMER ASSEMBLY
5950-01-123-0660 Two or more separable TRANSFORMER (as modified) on a common mounting or mounted on each other.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station
Part Alternates: ST30852, 11364, 3211805001, 321-18050-01, 3211805004, 321-18050-04, 861897E, 9848822B, 984882-2B, 5950-01-123-0660, 01-123-0660, 5950011230660, 011230660
Electrical and Electronic Equipment Components | Coils and Transformers
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 05 DEC 1981 | 01-123-0660 | 00449 ( TRANSFORMER ASSEMBLY ) |
Cross Reference | NSN 5950-01-123-0660
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 11364 | 55196 | SORA POWER INC. DBA SIGMA DIVISION |
| 321-18050-01 | 95266 | OECO, LLC DBA PACIFIC SCIENTIFIC OECO |
| 321-18050-04 | 95266 | OECO, LLC DBA PACIFIC SCIENTIFIC OECO |
| 861897E | 82577 | RAYTHEON COMPANY DBA RAYTHEON |
| 984882-2B | 82577 | RAYTHEON COMPANY DBA RAYTHEON |
| ST30852 | 97102 | STERLING TRANSFORMER CORP |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5950-01-123-0660
Related Products | NSN 5950-01-123-0660
Technical Data | NSN 5950-01-123-0660
| Characteristic | Specifications |
|---|---|
| TERMINAL TYPE AND QUANTITY | 35 WIRE LEAD |
| (NON-CORE DATA) COMPONENT NAME AND QUANTITY | 2 TRANSFORMER |
| (NON-CORE DATA) WINDING TAP LOCATION | CENTER TAP 1ST COMPONENT 1ST SECONDARY CENTER TAP 1ST COMPONENT 4TH SECONDARY CENTER TAP 1ST COMPONENT SINGLE PRIMARY CENTER TAP 2ND COMPONENT 1ST SECONDARY TAP W/O CENTER TAP 2ND COMPONENT 2ND SECONDARY TAP W/O CENTER TAP 2ND COMPONENT 3RD SECONDARY TAP W/CENTER TAP 2ND COMPONENT SINGLE PRIMARY |
| RATING METHOD | ELECTRICAL ALL COMPONENTS ALL PRIMARY ELECTRICAL ALL COMPONENTS ALL SECONDARY |
| WINDING OPERATING VOLTAGE | 12.02 AC VOLTS NOMINAL 1ST COMPONENT 1ST SECONDARY 70.70 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY 149.88 AC VOLTS NOMINAL 1ST COMPONENT 3RD SECONDARY 12.02 AC VOLTS NOMINAL 1ST COMPONENT 4TH SECONDARY 28.28 AC VOLTS NOMINAL 1ST COMPONENT SINGLE PRIMARY 32.52 AC VOLTS NOMINAL 2ND COMPONENT 1ST SECONDARY 130.00 DC VOLTS NOMINAL AND 133.50 DC VOLTS NOMINAL AND 137.00 DC VOLTS NOMINAL 2ND COMPONENT 2ND SECONDARY 178.16 AC VOLTS NOMINAL AND 195.83 AC VOLTS NOMINAL AND 213.51 AC VOLTS NOMINAL 2ND COMPONENT 3RD SECONDARY |
| WINDING OPERATING CURRENT | 50.0 MILLIAMPERES AC MAXIMUM 1ST COMPONENT 1ST SECONDARY 50.0 MILLIAMPERES AC MAXIMUM 1ST COMPONENT 2ND SECONDARY 35.0 MILLIAMPERES AC MAXIMUM 1ST COMPONENT 3RD SECONDARY 3.0 AMPERES AC MAXIMUM 1ST COMPONENT 4TH SECONDARY 10.0 MILLIAMPERES AC MAXIMUM 2ND COMPONENT 1ST SECONDARY 1.2 AMPERES AC MAXIMUM 2ND COMPONENT 2ND SECONDARY 35.0 MILLIAMPERES AC MAXIMUM 2ND COMPONENT 3RD SECONDARY |
| FREQUENCY RATING | 10.0 KILOHERTZ NOMINAL ALL COMPONENTS |
| WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL ALL COMPONENTS |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 4 SECONDARY 1ST COMPONENT 1 PRIMARY AND 3 SECONDARY 2ND COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE |
Restrictions/Controls & Freight Information | NSN 5950-01-123-0660
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
| Less than car load rating | ||
| Less than truck load rating | W | Rating Variable |
| Water commodity Code | 595 | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5950-01-123-0660
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9N | Navy-owned stocks of defense electronic material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | S9E | Defense Supply Center Columbus Columbus, OH 43218 |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |