Product Details | POWER TRANSFORMER

5950-01-202-9262 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 5950-01-202-9262, 01-202-9262, 5950012029262, 012029262

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 01-202-9262

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-202-9262

Technical Data | NSN 5950-01-202-9262

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 16 WIRE LEAD
(NON-CORE DATA) WINDING TAP LOCATION TAP W/CENTER TAP SINGLE COMPONENT ALL PRIMARY
WINDING OPERATING VOLTAGE 28.50 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE TERTIARY 76.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY 1.58 AC KILOVOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY
WINDING OPERATING CURRENT 100.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE TERTIARY 10.0 AMPERES AC MAXIMUM SINGLE COMPONENT ALL PRIMARY 225.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY
FREQUENCY RATING 20.0 KILOHERTZ NOMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 2 PRIMARY AND 3 SECONDARY AND 1 TERTIARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD THREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 3 SINGLE GROUP
THREAD SERIES DESIGNATOR UNF SINGLE GROUP
NOMINAL THREAD SIZE 0.190 INCHES SINGLE GROUP
(NON-CORE DATA) THREAD CLASS 2B SINGLE GROUP
(NON-CORE DATA) THREAD DIRECTION RIGHT-HAND SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE 6.380 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE BASE OF AN ISOSCELES TRIANGLE 4.880 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE HERMETICALLY SEALED WITH OIL
BODY LENGTH 6.020 INCHES NOMINAL
BODY HEIGHT 6.140 INCHES NOMINAL
BODY WIDTH 4.530 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
(NON-CORE DATA) UNPACKAGED UNIT WEIGHT 9.000 POUNDS
(NON-CORE DATA) CUBIC MEASURE 167.4 CUBIC INCHES

Restrictions/Controls & Freight Information | NSN 5950-01-202-9262

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Category Code Description
No Freight Information