Product Details | POWER TRANSFORMER

5950-01-214-4200 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 14067, 1898, 3L0146E001, 5950-01-214-4200, 01-214-4200, 5950012144200, 012144200

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 10 AUG 1985 01-214-4200

Cross Reference | NSN 5950-01-214-4200

Part Number Cage Code Manufacturer
14067 53854 MAGNESPEC, INC.
1898 23591 FRICK-GALLAGHER MFG. CO.
3L0146E001 22915 NORTHROP GRUMMAN CORP ELECTRONIC SYSTEMS DEFENSIVE SYSTEM

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-214-4200

Technical Data | NSN 5950-01-214-4200

Characteristic Specifications
MOUNTING METHOD TERMINAL SINGLE GROUP
WINDING OPERATING CURRENT 0.196 AMPERES AC MINIMUM AND 0.204 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD PRIMARY
WINDING OPERATING VOLTAGE 10.44 AC VOLTS MINIMUM AND 10.86 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND PRIMARY
WINDING OPERATING CURRENT 0.098 AMPERES DC MINIMUM AND 0.102 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
FREQUENCY RATING 18.5 KILOHERTZ MINIMUM AND 25.6 KILOHERTZ MAXIMUM SINGLE COMPONENT
WINDING TAP LOCATION (NON-CORE) UNABLE TO DECODE
OVERALL LENGTH 1.800 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
WINDING OPERATING CURRENT 10.78 AMPERES DC MINIMUM AND 11.22 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH PRIMARY
WINDING OPERATING CURRENT 0.137 AMPERES DC MINIMUM AND 0.143 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND PRIMARY
WINDING OPERATING VOLTAGE 35.47 AC VOLTS MINIMUM AND 36.91 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY
OVERALL WIDTH 1.800 INCHES NOMINAL
OVERALL HEIGHT 0.900 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY 26 PIN
WINDING OPERATING CURRENT 0.54 AMPERES DC MINIMUM AND 0.56 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE 64.70 AC VOLTS MINIMUM AND 67.60 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST PRIMARY
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
WINDING OPERATING VOLTAGE 28.17 AC VOLTS MINIMUM AND 29.31 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE 20.87 AC VOLTS MINIMUM AND 21.73 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE 6.26 AC VOLTS MINIMUM AND 6.52 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD PRIMARY
WINDING FUNCTION AND QUANTITY 4 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
WINDING OPERATING VOLTAGE 6.02 AC VOLTS MINIMUM AND 6.26 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH PRIMARY
INCLOSURE TYPE FULLY INCLOSED
WINDING OPERATING CURRENT 0.147 AMPERES DC MINIMUM AND 0.153 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY

Restrictions/Controls & Freight Information | NSN 5950-01-214-4200

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code SU Ogden Air Logistics Center
Hill AFB, UT 84056-5609
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-01-214-4200

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeAISU:ADVANCED INTERCONTINENTAL BALLISTIC (MX)
Price ValidationE The current standard price is an estimated price.
  • Estimated Price challenges are allowed, but follow procedures in para 60.b. (3) of section L of this manual.
  • This code will be changed to a P code upon notification of a contract price or this code will be changed to an updated code upon determination of a valid price.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each