NSN 5950-01-215-4710 G641339, 10P5CT, 01-215-4710
Product Details | POWER TRANSFORMER
5950-01-215-4710 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station
Part Alternates: G641339, 10P5CT, 5950-01-215-4710, 01-215-4710, 5950012154710, 012154710
Electrical and Electronic Equipment Components | Coils and Transformers
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 25 AUG 1985 | 01-215-4710 | 32496 ( TRANSFORMER, POWER ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5950-01-215-4710
Technical Data | NSN 5950-01-215-4710
| Characteristic | Specifications |
|---|---|
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.234 INCHES MINIMUM AND 1.266 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
| WINDING TAP LOCATION (NON-CORE) | UNABLE TO DECODE |
| WINDING OPERATING CURRENT | 2.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
| MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| OVERALL LENGTH | 2.032 INCHES MINIMUM AND 2.094 INCHES MAXIMUM |
| MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
| BODY WIDTH | 1.750 INCHES NOMINAL |
| MAXIMUM TRANSFORMER POWER RATING | 10.0 VOLT-AMPERE SINGLE COMPONENT |
| TERMINAL TYPE AND QUANTITY | 5 WIRE HOOK |
| THREAD CLASS (NON-CORE) | UNABLE TO DECODE |
| WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| THREAD DIRECTION (NON-CORE) | UNABLE TO DECODE |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| UNPACKAGED UNIT WEIGHT (NON-CORE) | 1.500 POUNDS |
| OVERALL WIDTH | 1.719 INCHES MINIMUM AND 1.781 INCHES MAXIMUM |
| CUBIC MEASURE (NON-CORE) | 9.9 CUBIC INCHES |
| FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| BODY LENGTH | 2.750 INCHES NOMINAL |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
| INCLOSURE TYPE | FULLY INCLOSED |
| BODY HEIGHT | 2.062 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.484 INCHES MINIMUM AND 1.516 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| OVERALL HEIGHT | 3.001 INCHES MINIMUM AND 3.249 INCHES MAXIMUM |
| WINDING OPERATING VOLTAGE | 5.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
Restrictions/Controls & Freight Information | NSN 5950-01-215-4710
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
| Less than car load rating | ||
| Less than truck load rating | W | Rating Variable |
| Water commodity Code | 595 | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5950-01-215-4710
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |