Product Details | POWER TRANSFORMER

5950-01-217-4091 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: D-351, T16130, T-16130, 16130, 240-676.29, 24067629, D351, 5950-01-217-4091, 01-217-4091, 5950012174091, 012174091

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 26 SEP 1985 01-217-4091

Demand History | NSN 5950-01-217-4091

Part Number Request Date QTY Origin
5950-01-217-4091 2014-05-148 2 DIBBS
5950-01-217-4091 2013-10-304 2 DIBBS
5950-01-217-4091 2012-04-108 2 US

Cross Reference | NSN 5950-01-217-4091

Part Number Cage Code Manufacturer
16130 05853 PTC TRANSFORMERS
240-676.29 03040 POWER CONTROL DEVICES, INC. DBA AMERICAN TIME PRODUCTS
D-351 26522 B G LABORATORIES INC.
T-16130 05853 PTC TRANSFORMERS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-217-4091

Technical Data | NSN 5950-01-217-4091

Characteristic Specifications
MAXIMUM OPERATING TEMP 90.0 DEG CELSIUS
WINDING TAP LOCATION (NON-CORE) UNABLE TO DECODE
WINDING OPERATING CURRENT 5.0 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE 31.60 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
BODY HEIGHT 2.680 INCHES MAXIMUM
THREAD SERIES DESIGNATOR UNC SINGLE GROUP
BODY LENGTH 3.875 INCHES NOMINAL
MOUNTING METHOD THREADED HOLE SINGLE GROUP
RELIABILITY INDICATOR NOT ESTABLISHED
SPECIAL FEATURES 1 PRIMARY AND 5 SECONDARY WINDINGS; FIFTH SECONDARY IS CENTER TAPED WITH 16.70 VOLTS AND 3 AMPS OF CURRENT WHICH HAS BEEN RECTIFIED
WINDING OPERATING VOLTAGE 15.20 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING CURRENT 250.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE 29.50 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
TERMINAL TYPE AND QUANTITY 15 TAB, SOLDER LUG
WINDING OPERATING CURRENT 2.0 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
THREAD CLASS (NON-CORE) UNABLE TO DECODE
WINDING OPERATING VOLTAGE 26.20 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
THREAD DIRECTION (NON-CORE) UNABLE TO DECODE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.687 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CUBIC MEASURE (NON-CORE) 2.6 CUBIC INCHES
WINDING OPERATING CURRENT 6.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
NOMINAL THREAD SIZE 0.190 INCHES SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
WINDING SHIELDING METHOD CORE GROUNDED SINGLE COMPONENT
FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING OPERATING CURRENT 500.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 5 SECONDARY SINGLE COMPONENT
INCLOSURE TYPE FULLY INCLOSED
BODY WIDTH 3.250 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5950-01-217-4091

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code TH Defense Supply Center Columbus
Columbus, OH 43215
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-01-217-4091

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Price ValidationE The current standard price is an estimated price.
  • Estimated Price challenges are allowed, but follow procedures in para 60.b. (3) of section L of this manual.
  • This code will be changed to a P code upon notification of a contract price or this code will be changed to an updated code upon determination of a valid price.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each