Product Details | POWER TRANSFORMER

5950-01-222-4442 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 11780, 117804, 11780-4, 31001838801, 310-018388-01, 3101872101, 310-18721-01, 862398, 9847174B, 984717-4B, 5950-01-222-4442, 01-222-4442, 5950012224442, 012224442

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 12 DEC 1985 01-222-4442

Demand History | NSN 5950-01-222-4442

Part Number Request Date QTY Origin
11780 2025-01-15 2 US

Cross Reference | NSN 5950-01-222-4442

Part Number Cage Code Manufacturer
11780 55196 SORA POWER INC. DBA SIGMA DIVISION
11780-4 55196 SORA POWER INC. DBA SIGMA DIVISION
310-018388-01 95266 OECO, LLC DBA PACIFIC SCIENTIFIC OECO
310-18721-01 95266 OECO, LLC DBA PACIFIC SCIENTIFIC OECO
862398 82577 RAYTHEON COMPANY DBA RAYTHEON
984717-4B 82577 RAYTHEON COMPANY DBA RAYTHEON

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-222-4442

Technical Data | NSN 5950-01-222-4442

Characteristic Specifications
BODY HEIGHT 3.280 INCHES MAXIMUM
WINDING OPERATING CURRENT 6.0 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
FREQUENCY RATING 15.0 KILOHERTZ NOMINAL SINGLE COMPONENT
WINDING TAP LOCATION (NON-CORE) UNABLE TO DECODE
MOUNTING METHOD UNTHREADED HOLE SINGLE GROUP
WINDING OPERATING VOLTAGE 31.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING CURRENT 275.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST PRIMARY
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
RELIABILITY INDICATOR NOT ESTABLISHED
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
MAXIMUM OPERATING TEMP 130.0 DEG CELSIUS
SPECIAL FEATURES ALL SECONDARY OUTPUTS ARE DISPLAYED AS RECTIFIED VOLTAGES; 2ND SECONDARY PROVIDES A NEGATIVE VOLTAGE OUTPUT; SECONDARIES 3,4,5 PROVIDE POS AND NEG VOLTAGE OUTPUTS; 5TH SECONDARY OUTPUTS ARE POS 57.00 OR NEG 57.00 V DC W/ 0.5 AMPS MIN AND 1.0 AMPS MAX; 3 PRIMARY WINDINGS AND 5 SECONDARY WINDINGS
WINDING OPERATING CURRENT 10.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD PRIMARY
WINDING OPERATING VOLTAGE 19.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING CURRENT 0.5 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND PRIMARY
BODY LENGTH 3.000 INCHES MAXIMUM
BODY WIDTH 1.780 INCHES MAXIMUM
WINDING FUNCTION AND QUANTITY 3 PRIMARY AND 5 SECONDARY SINGLE COMPONENT
UNPACKAGED UNIT WEIGHT (NON-CORE) 1.600 POUNDS
MOUNTING HOLE DIAMETER 0.156 INCHES NOMINAL SINGLE GROUP
WINDING OPERATING VOLTAGE 8.48 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY
WINDING OPERATING VOLTAGE 268.66 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY
WINDING OPERATING VOLTAGE 10.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT 12.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
TERMINAL TYPE AND QUANTITY 24 TAB, SOLDER LUG
CUBIC MEASURE (NON-CORE) 17.5 CUBIC INCHES
WINDING OPERATING VOLTAGE 10.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
WINDING OPERATING VOLTAGE 57.55 AC VOLTS NOMINAL SINGLE COMPONENT 3RD PRIMARY
WINDING OPERATING CURRENT 2.3 AMPERES DC MINIMUM AND 5.1 AMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING CURRENT 15.0 AMPERES DC MINIMUM AND 20.0 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
INCLOSURE TYPE FULLY INCLOSED
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP

Restrictions/Controls & Freight Information | NSN 5950-01-222-4442

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code TH Defense Supply Center Columbus
Columbus, OH 43215
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-01-222-4442

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Price ValidationE The current standard price is an estimated price.
  • Estimated Price challenges are allowed, but follow procedures in para 60.b. (3) of section L of this manual.
  • This code will be changed to a P code upon notification of a contract price or this code will be changed to an updated code upon determination of a valid price.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each