Product Details | POWER TRANSFORMER

5950-01-223-0005 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 902C781501020, 902C7815-01-020, S101, 5950-01-223-0005, 01-223-0005, 5950012230005, 012230005

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 21 DEC 1985 01-223-0005

Drawings & Photos | NSN 5950-01-223-0005


Demand History | NSN 5950-01-223-0005

Part Number Request Date QTY Origin
S101 2014-11-316 6 Turkey

Cross Reference | NSN 5950-01-223-0005

Part Number Cage Code Manufacturer
902C7815-01-020 86360 GE AVIATION SYSTEMS LLC DBA GE AVIATION DIV INFORMATION
S101 26522 B G LABORATORIES INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-223-0005

Technical Data | NSN 5950-01-223-0005

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 17 WIRE LEAD
WINDING OPERATING VOLTAGE 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT 0.3 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
MAXIMUM TRANSFORMER POWER RATING 9.0 WATTS SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND
INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO SINGLE PHASE AND
MOUNTING METHOD FLANGE AND
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
MOUNTING HOLE DIAMETER 0.154 INCHES NOMINAL SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.813 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE FULLY INCLOSED
OVERALL LENGTH 2.750 INCHES MAXIMUM
OVERALL HEIGHT 1.400 INCHES MAXIMUM
OVERALL WIDTH 2.260 INCHES MAXIMUM
FEATURES PROVIDED TINNED WIRE LEADS
RELIABILITY INDICATOR NOT ESTABLISHED
SPECIAL FEATURES 1 PRIMARY WINDING; 5 SECONDARY WINDINGS
III TRANSFORMER WINDING CONNECTION TYPE WYE-DELTA
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION FLAME RESISTANT AND
MANUFACTURERS CODE 86360
MFR SOURCE CONTROLLING REFERENCE 902C7815-01-020

Restrictions/Controls & Freight Information | NSN 5950-01-223-0005

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code KE Naval ICP
Philadelphia, PA 19111
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-01-223-0005

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each