Product Details | POWER TRANSFORMER

5950-01-223-2816 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 3253202, 325320-2, 5950-01-223-2816, 01-223-2816, 5950012232816, 012232816

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 25 DEC 1985 01-223-2816

Demand History | NSN 5950-01-223-2816

Part Number Request Date QTY Origin
5950-01-223-2816 2012-09-262 1 DIBBS
5950-01-223-2816 2008-12-364 2 DIBBS
5950-01-223-2816 2008-12-364 3 DIBBS
5950-01-223-2816 2008-12-364 5 DIBBS
5950-01-223-2816 2007-12-347 5 DIBBS
5950-01-223-2816 2007-10-297 2 DIBBS
5950-01-223-2816 2007-10-295 3 DIBBS

Cross Reference | NSN 5950-01-223-2816

Part Number Cage Code Manufacturer
325320-2 96214 RAYTHEON COMPANY DBA RAYTHEON

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-223-2816

Technical Data | NSN 5950-01-223-2816

Characteristic Specifications
WINDING POWER RATING 27.5 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY
BODY LENGTH 2.300 INCHES MAXIMUM
UNPACKAGED UNIT WEIGHT (NON-CORE) 0.850 POUNDS
TERMINAL TYPE AND QUANTITY 5 TAB, SOLDER LUG
NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP
WINDING TAP LOCATION (NON-CORE) UNABLE TO DECODE
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
THREAD SERIES DESIGNATOR UNC SINGLE GROUP
WINDING OPERATING VOLTAGE 102.00 AC VOLTS MINIMUM AND 124.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
MOUNTING METHOD THREADED HOLE SINGLE GROUP
RELIABILITY INDICATOR NOT ESTABLISHED
BODY WIDTH 2.100 INCHES MAXIMUM
WINDING OPERATING VOLTAGE 13.75 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
THREAD CLASS (NON-CORE) UNABLE TO DECODE
THREAD DIRECTION (NON-CORE) UNABLE TO DECODE
BODY HEIGHT 2.000 INCHES MAXIMUM
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.394 INCHES MINIMUM AND 1.414 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.730 INCHES MINIMUM AND 1.750 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM OPERATING TEMP 155.0 DEG CELSIUS
INCLOSURE TYPE FULLY INCLOSED
WINDING OPERATING CURRENT 2.0 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY

Restrictions/Controls & Freight Information | NSN 5950-01-223-2816

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-01-223-2816

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each