Product Details | POWER TRANSFORMER

5950-01-227-9034 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: T0942, T-0942, 847433, 5950-01-227-9034, 01-227-9034, 5950012279034, 012279034

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 12 MAR 1986 01-227-9034

Demand History | NSN 5950-01-227-9034

Part Number Request Date QTY Origin
5950-01-227-9034 2015-09-259 1 DIBBS
5950-01-227-9034 2015-08-235 1 DIBBS
5950-01-227-9034 2014-07-190 1 DIBBS

Cross Reference | NSN 5950-01-227-9034

Part Number Cage Code Manufacturer
847433 98749 SACRAMENTO AIR LOGISTICS CENTER SM-ALC/LIIL
T-0942 12867 GSE HOLDINGS INC. DBA ITW MILITARY GSE

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-227-9034

Technical Data | NSN 5950-01-227-9034

Characteristic Specifications
MOUNTING FACILITY QUANTITY 4 ALL GROUPINGS
WINDING OPERATING VOLTAGE 21.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT 95.0 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT 425.0 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY
THREAD DIRECTION (NON-CORE) ERR-070
MOUNTING METHOD BRACKET ALL GROUPINGS AND THREADED HOLE ALL GROUPINGS
NOMINAL THREAD SIZE 0.250 INCHES 2ND GROUP
NOMINAL THREAD SIZE 0.375 INCHES 1ST GROUP
RELIABILITY INDICATOR NOT ESTABLISHED
MAXIMUM TRANSFORMER POWER RATING 18.3 KILOVOLT-AMPERE SINGLE COMPONENT
OVERALL LENGTH 16.000 INCHES NOMINAL
WINDING OPERATING VOLTAGE 21.80 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
INCLOSURE TYPE OPEN
THREAD SERIES DESIGNATOR UNC ALL GROUPINGS
THREAD CLASS (NON-CORE) ERR-070
WINDING OPERATING VOLTAGE 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
OVERALL HEIGHT 11.120 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 8.000 INCHES NOMINAL ALL MOUNTING FACILITIES SINGLE CENTER GROUP
WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
BODY HEIGHT 6.500 INCHES NOMINAL
FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
OVERALL WIDTH 6.500 INCHES NOMINAL
BODY WIDTH 11.120 INCHES NOMINAL
INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO THREE PHASE SINGLE COMPONENT
TRANSFORMER WINDING CONNECTION TYPE WYE-OPEN DELTA AND WYE-WYE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 15.000 INCHES NOMINAL ALL MOUNTING FACILITIES SINGLE CENTER GROUP
WINDING OPERATING CURRENT 425.0 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY
TERMINAL TYPE AND QUANTITY 12 WIRE LEAD W/LUG

Restrictions/Controls & Freight Information | NSN 5950-01-227-9034

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code TH Defense Supply Center Columbus
Columbus, OH 43215
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-01-227-9034

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Price ValidationE The current standard price is an estimated price.
  • Estimated Price challenges are allowed, but follow procedures in para 60.b. (3) of section L of this manual.
  • This code will be changed to a P code upon notification of a contract price or this code will be changed to an updated code upon determination of a valid price.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each