Product Details | POWER TRANSFORMER

5950-01-231-8886 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: CPP741, 172A1361, 5950-01-231-8886, 01-231-8886, 5950012318886, 012318886

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 06 MAY 1986 01-231-8886

Cross Reference | NSN 5950-01-231-8886

Part Number Cage Code Manufacturer
172A1361 05606 GENERAL DYNAMICS-OTS, INC. DBA GD-OTS (WILLISTON)
CPP741 15634 MAGNETIKA, INC
CPP741 80223 UNITED TRANSFORMER CORP SUB OF OPT INDUSTRIES INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-231-8886

Technical Data | NSN 5950-01-231-8886

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 5 TAB, SOLDER LUG
WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
RELIABILITY INDICATOR NOT ESTABLISHED
OVERALL LENGTH 2.875 INCHES MAXIMUM
OVERALL WIDTH 2.875 INCHES MAXIMUM
OVERALL HEIGHT 2.500 INCHES MAXIMUM
FREQUENCY RATING 60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPE FULLY INCLOSED
WINDING OPERATING CURRENT 4.00 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY

Restrictions/Controls & Freight Information | NSN 5950-01-231-8886

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information