Product Details | POWER TRANSFORMER

5950-01-233-3288 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 408695, 5950-01-233-3288, 01-233-3288, 5950012333288, 012333288

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 29 MAY 1986 01-233-3288

Cross Reference | NSN 5950-01-233-3288

Part Number Cage Code Manufacturer
408695 12909 CARDION INC
408695 20284 TARGET CORPORATION DBA TARGET

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-233-3288

Technical Data | NSN 5950-01-233-3288

Characteristic Specifications
WINDING OPERATING VOLTAGE 24.40 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
SPECIAL FEATURES 2 PRIMARY WINDINGS; 5 SECONDARY WINDINGS
WINDING OPERATING CURRENT 12.4 AMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING SHIELDING METHOD INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
WINDING OPERATING CURRENT 10.0 AMPERES AC NOMINAL SINGLE COMPONENT ALL PRIMARY
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION HUMIDITY RESISTANT AND VIBRATION RESISTANT
OVERALL WIDTH 5.500 INCHES MAXIMUM
OVERALL HEIGHT 7.300 INCHES MAXIMUM
WINDING OPERATING CURRENT 150.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY
MAXIMUM OPERATING TEMP 80.0 DEG CELSIUS
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
RELIABILITY INDICATOR NOT ESTABLISHED
TERMINAL TYPE AND QUANTITY 18 PIN
CUBIC MEASURE (NON-CORE) 393.47 CUBIC INCHES
WINDING OPERATING VOLTAGE 120.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY
WINDING OPERATING CURRENT 3.9 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY
FREQUENCY RATING 47.0 HERTZ MINIMUM SINGLE COMPONENT AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT
WINDING TAP LOCATION (NON-CORE) ERR-070
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 8.297 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
WINDING FUNCTION AND QUANTITY 2 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT
WINDING OPERATING VOLTAGE 103.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE 42.20 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
WINDING OPERATING VOLTAGE 51.10 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
WINDING OPERATING CURRENT 22.0 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY
MOUNTING SLOT WIDTH 0.300 INCHES NOMINAL SINGLE GROUP
OVERALL LENGTH 9.800 INCHES MAXIMUM
MOUNTING METHOD SLOT SINGLE GROUP
INCLOSURE TYPE FULLY INCLOSED

Restrictions/Controls & Freight Information | NSN 5950-01-233-3288

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code CH Defense Supply Center Richmond
Richmond, VA 23297
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-01-233-3288

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Price ValidationE The current standard price is an estimated price.
  • Estimated Price challenges are allowed, but follow procedures in para 60.b. (3) of section L of this manual.
  • This code will be changed to a P code upon notification of a contract price or this code will be changed to an updated code upon determination of a valid price.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each