Product Details | POWER TRANSFORMER

5950-01-266-6107 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: LO3868, 1149441, 114944-1, 216BU, 5950-01-266-6107, 01-266-6107, 5950012666107, 012666107

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 29 OCT 1987 01-266-6107

Demand History | NSN 5950-01-266-6107

Part Number Request Date QTY Origin
5950-01-266-6107 2025-04-93 3 DIBBS
5950-01-266-6107 2023-01-25 2 DIBBS
5950-01-266-6107 2016-04-94 2 DIBBS
5950-01-266-6107 2010-11-305 4 DIBBS

Cross Reference | NSN 5950-01-266-6107

Part Number Cage Code Manufacturer
114944-1 94271 LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN
216BU 58474 SUPERIOR ELECTRIC HOLDING GROUP LLC DBA SUPERIOR ELECTRIC
LO3868 16236 DLA LAND AND MARITIME

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-266-6107

Technical Data | NSN 5950-01-266-6107

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 7 TERMINAL BLOCK W/SCREWS
(NON-CORE DATA) WINDING TAP LOCATION MULTIPLE TAPS W/CENTER TAP SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY 0.00 AC MEGAVOLTS MINIMUM AND 280.00 AC MEGAVOLTS MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING CURRENT 3.5 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING 50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
MAXIMUM TRANSFORMER POWER RATING 0.42 KILOVOLT-AMPERE SINGLE COMPONENT
ADJUSTMENT METHOD AND QUANTITY 1 ADJUSTABLE CONTROL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY, VARIABLE AUTOTRANSFORMER TYPE SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD SLOT SINGLE GROUP
MOUNTING FACILITY QUANTITY 7 SINGLE GROUP
MOUNTING SLOT WIDTH 0.250 INCHES NOMINAL SINGLE GROUP
INCLOSURE TYPE FULLY INCLOSED
OVERALL LENGTH 5.810 INCHES NOMINAL
OVERALL DIAMETER 6.090 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
SPECIAL FEATURES ITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE SUPPLY CENTER COLUMBUS PRODUCTION STANDARD NO. LO6107
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS REFERENCE NUMBER DIFFERENTIATING MATERIAL WILL BE IN ACCORDANCE WITH NAVAL INVENTORY CONTROL POINT ACTIVITY HX QUALITY CONTROL. MANUFACTURING AND TESTING SPECIFICATIONS AVAILABLE AT THE DLA ICP
CRITICALITY CODE JUSTIFICATION ZZZY
MANUFACTURERS CODE 94271
DESIGN CONTROL REFERENCE 114944-1

Restrictions/Controls & Freight Information | NSN 5950-01-266-6107

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:SThe item is a non-aviation Critical Safety Item (CSI) whose failure will result in serious damage to equipment or serious injury or death to personnel.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-01-266-6107

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each